Quiz 7: Treatment Delivery Equipment
Nursing
Q 1Q 1
Installation of the first fully isocentric linear accelerator in the United States was in:
A) 1942
B) 1952
C) 1961
D) 1979
Free
Multiple Choice
C The first fully isocentric linear accelerator was manufactured and installed in the United States in 1961 by Varian Associates.
Q 2Q 2
Which of the following is not found inside the head of a linear accelerator?
A) ion chambers
B) target
C) accelerator structure
D) bending magnet
E) scattering foil
Free
Multiple Choice
C The ion chambers,target,bending magnet,and scattering foil are found in the treatment head.
Q 3Q 3
Which of the following best describes the major components of a linear accelerator?
A) power supply,modulator,electron gun,accelerating waveguide,head,beryllium target
B) power supply,modulator,klystron,electron gun,"D"s,beryllium target
C) power supply,electron gun,accelerating waveguide,head,doughnut accelerator structure
D) modulator,klystron,electron gun,accelerator structure,waveguide,bending magnet
Free
Multiple Choice
D The modulator is a component on higher energy beams.The klystron,which is the source of microwave power,delivers the microwaves via the waveguide.The electron gun in the gantry provides the source of electrons to be accelerated.The bending magnet helps focus the electrons to the target.
Q 4Q 4
Which of the following best describes the order in which electron bunches and the resulting x-rays travel through the head of a linear accelerator?
A) bending magnet,dose chambers,target,flattening filter,wedge
B) bending magnet,target,dose chambers,primary collimator,wedge,flattening filter
C) bending magnet,target,primary collimator,flattening filter,wedge,dose chamber
D) bending magnet,target,primary collimator,flattening filter,dose chamber,MLC
E) bending magnet,dose chambers,target,flattening filter,primary collimator,MLC
Free
Multiple Choice
Q 5Q 5
Electron beams __________________.
A) require a flattening filter to make the electron beam profile symmetric and flat
B) require a scattering foil to make the electron beam profile symmetric and flat
C) interact with the transmission target before leaving the exit window
D) a,b,and c are true
E) b and c are true
Free
Multiple Choice
Q 6Q 6
The electron gun is similar to what part of an x-ray tube?
A) anode
B) rotating tungsten target
C) cathode
D) power supply
Free
Multiple Choice
Q 7Q 7
A bending magnet in an accelerator may be used:
A) to help deflect microwave power
B) to deflect (bend)the electron beam
C) gather stray electrons together in a bunch
D) gather random paper clips
Free
Multiple Choice
Q 8Q 8
In treatments using kilovoltage equipment,filters are used to:
A) filter low-energy x-rays
B) shield the patient from all radiation exposure
C) collimate the beam
D) increase quantity
Free
Multiple Choice
Free
Multiple Choice
Q 10Q 10
The energy of a cobalt unit is:
A) 1.36 and 1.01 MeV
B) .662 and 1.5 MeV
C) 1.00 and 1.5 MeV
D) 1.17 and 1.33 MeV
Free
Multiple Choice
Q 11Q 11
The rate of decay per month on a cobalt 60 unit is:
A) 1% per month
B) 2% per month
C) 3% per month
D) 5% per month
Free
Multiple Choice
Q 12Q 12
A(n)_______________ test is performed on the cobalt 60 unit to determine whether the source's seal is broken.
A) penumbra
B) light field-radiation field coincidence
C) electron equilibrium
D) wipe
Free
Multiple Choice
Q 13Q 13
Choose the most accurate statement.
A) The penumbra from a Co-60 machine is smaller than that from a linear accelerator because the Co-60 source diameter is 3 mm.
B) The penumbra from a Co-60 machine is smaller than that from a linear accelerator because Co-60 has a source travel timer error.
C) The penumbra from a Co-60 machine is larger than that from a linear accelerator because Co-60 has a source travel timer error.
D) The penumbra from a Co-60 machine is larger than that from a linear accelerator because the Co-60 source diameter is 3 mm.
Free
Multiple Choice
Q 14Q 14
Which of the following limited the use of orthovoltage x-ray machines for radiation therapy?
A) skin dose tolerance
B) proton contamination
C) excessive dose rate
D) neutron contamination
E) Nuclear Regulatory Commission requirement
Free
Multiple Choice
Q 15Q 15
Choose the most correct statement concerning Co-60 teletherapy.
A) A timer error factor must be added to the treatment time.
B) The head contains the source,shielding,and collimators.
C) The Co-60 source is 1 to 3 cm in diameter.
D) Co-60 emits two -rays whose average energy is 1.25 MeV.
E) All of the above are true.
Free
Multiple Choice
Q 16Q 16
The circulator in a linear accelerator:
A) mixes the hot and cold water to get the right temperature
B) spins the electrons in the right direction
C) conducts microwaves from the RF driver into the klystron
D) isolates the klystron from reflected microwave power
Free
Multiple Choice
Q 17Q 17
Of the following treatment units,which has the least amount of skin sparing?
A) orthovoltage
B) cobalt
C) 4 MV beam
D) 10 MV beam
Free
Multiple Choice
Q 18Q 18
When treating with electrons,the carousel rotates to place a _________________ in the beam to spread it out.
A) collimator
B) cone
C) scattering foil
D) flattening filter
Free
Multiple Choice
Q 19Q 19
Image-guided radiation therapy can be accomplished with: I.ultrasound units
II)CT scanner
III)kV imager
IV)cone beam
V)simulator
A) I,III,and IV
B) II,III,and V
C) I,II,III,and IV
D) III,IV,and V
Free
Multiple Choice
Q 20Q 20
Orthovoltage x-ray machines have energies in the range of:
A) 1 kV to 100 kV
B) 150 kV to 500 kV
C) 200 MeV to 400 MeV
D) none of the above
Free
Multiple Choice
Q 21Q 21
A Van de Graaff machine __________________. I.is an electrostatic generator
II)operates at 2 MV
III)operates a 200 kV
IV)uses a doughnut-shaped accelerator structure
A) I and II
B) II and IV
C) III and IV
D) I and IV
Free
Multiple Choice
Free
Multiple Choice
Q 23Q 23
Lipowitz metal is composed of:
A) tin bismuth,lead and cadmium
B) lead,tungsten,tin
C) tin,bismuth,tungsten,lead
D) bismuth,cadmium and lead
Free
Multiple Choice
Q 24Q 24
When using multileaf collimation,which concerns need to be evaluated?
A) penumbra between the leaves and the transmission of the leaves
B) movement of MLCs during the treatment give variation in dose that need to be evaluated along with penumbra between the leaves
C) movement of MLCs during treatment and interleaf transmission leakage
D) penumbra at the end of the leaves and interleaf transmission leakage
Free
Multiple Choice
Q 25Q 25
Some of the more common medical accelerator hazards include: I.incorrect dose delivered
II)dose delivered to wrong area
III)machine collision
IV)emergency off malfunction
A) I,II,and IV
B) II,III,and IV
C) I,III,and IV
D) I,II,and III
Free
Multiple Choice
Q 26Q 26
Depth of maximum dose for a 10 MV machine is how far below the skin surface?
A) 0.5 cm
B) 1.5 cm
C) 2.5 cm
D) 5 cm
Free
Multiple Choice
Q 27Q 27
What is the penumbra of a cobalt 60 machine with a source size of 3 cm,an SSD of 80 cm,and a source-to-diaphragm distance of 30?
A) 1 cm
B) 2 cm
C) 4 cm
D) 5 cm
Free
Multiple Choice
Q 28Q 28
Depth of maximum dose for a 6 MV machine is how far below the skin surface?
A) 0.5 cm
B) 1.5 cm
C) 2.5 cm
D) 5 cm
Free
Multiple Choice
Q 29Q 29
Depth of maximum dose for a 15 MV machine is how far below the skin surface?
A) 0.5 cm
B) 1.5 cm
C) 2.5 cm
D) 3 cm
Free
Multiple Choice
Q 30Q 30
Inherent filtration is due to materials present in the x-ray tube itself that the beam must pass through.
Free
True False
Q 31Q 31
If a cobalt 60 source is stuck in the on position,you must retrieve the patient immediately and then push the source back in.
Free
True False