Deck 6: Demineralisation Plant Design and Water Treatment

Full screen (f)
exit full mode
Question
While designing the demineralisation plant what is considered as the weak acidic cation load?

A)alkaline hardness
B)alkaline hardness+ ema
C)ema
D)silica
Use Space or
up arrow
down arrow
to flip the card.
Question
While designing the demineralisation plant what is considered as the strong acidic cation load?

A)alkaline hardness
B)alkaline hardness + ema
C)ema
D)silica
Question
While designing the demineralisation plant what is considered as the strong basic anion load?

A)alkaline hardness
B)alkaline hardness + ema+co2
C)ema+silica
D)silica+co2+ alkalinity+ema
Question
While designing the demineralisation plant what is considered as the weak basic anion load?

A)alkaline hardness
B)alkaline hardness + ema
C)ema
D)silica
Question
When is strong basic anion not necessary?

A)silica is nil
B)co2 is nil
C)fluroine is nil
D)sulphate is nil
Question
When the hardness and alkalinity are around 30% what should be used?

A)sac
B)wac
C)wac, sac
D)wac, sac, wba
Question
In case along with silica, there is high content in sulphide and chloride what should be used?

A)wba
B)wba and sba
C)sba
D)sba,wba and wac
Question
For obtaining Silica<5 ppm which of these should be utilized?

A)sba followed by mixed be
B)sba
C)wba sba followed by mixed bed
D)mixed bed
Question
In which year was the Ferrosand process patented?

A)1960
B)1965
C)1970
D)1975
Question
What is the permitted concentration of manganese in drinking water?

A)30 g/l
B)40 g/l
C)50 g/l
D)60 g/l
Question
What is the permitted concentration of arsenic in drinking water?

A)10 g/l
B)20 g/l
C)30 g/l
D)40 g/l
Question
What is the minimum time of aeration?

A)20 minutes
B)40 minutes
C)60 minutes
D)80 minutes
Question
What is the tank volume of aeration for water flow of 50m3/h?

A)40 m3
B)50 m3
C)80 m3
D)100 m3
Question
At what pH should the water be maintained?

A)6.5
B)7.5
C)8.5
D)9
Question
The aeration system will decrease the redox potential of the water.
Question
What is the minimum required redox potential of water?

A)100 mv
B)200 mv
C)300 mv
D)400 mv
Question
Manganese oxidation requires a high oxidation potential.
Question
What is the desirable bed depth for AFM filtration?

A)1000 mm
B)1200 mm
C)1500 mm
D)1800 mm
Question
What is the maximum allowable flow for backwash?

A)20 m/hr
B)45 m/hr
C)60 m/hr
D)80 m/hr
Question
The fluoride concentration for prevention of dental caries is________                

A)1mg/l
B)2mg/l
C)3mg/l
D)4mg/l
Question
In which process, the fluoride content of water is raised?

A)chlorination
B)fluoridation
C)defluoridation
D)flocculation
Question
Which of the following is not used as a fluoride compound?

A)sodium fluoride
B)sodium silico fluoride
C)hydrofluosilicic acid
D)sodium fluro carbonate
Question
Which of the following is the pure compound?

A)sodium fluoride
B)sodium silico fluoride
C)hydrofluosilicic acid
D)sodium fluro carbonate
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/23
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 6: Demineralisation Plant Design and Water Treatment
1
While designing the demineralisation plant what is considered as the weak acidic cation load?

A)alkaline hardness
B)alkaline hardness+ ema
C)ema
D)silica
alkaline hardness
2
While designing the demineralisation plant what is considered as the strong acidic cation load?

A)alkaline hardness
B)alkaline hardness + ema
C)ema
D)silica
alkaline hardness + ema
3
While designing the demineralisation plant what is considered as the strong basic anion load?

A)alkaline hardness
B)alkaline hardness + ema+co2
C)ema+silica
D)silica+co2+ alkalinity+ema
silica+co2+ alkalinity+ema
4
While designing the demineralisation plant what is considered as the weak basic anion load?

A)alkaline hardness
B)alkaline hardness + ema
C)ema
D)silica
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
5
When is strong basic anion not necessary?

A)silica is nil
B)co2 is nil
C)fluroine is nil
D)sulphate is nil
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
6
When the hardness and alkalinity are around 30% what should be used?

A)sac
B)wac
C)wac, sac
D)wac, sac, wba
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
7
In case along with silica, there is high content in sulphide and chloride what should be used?

A)wba
B)wba and sba
C)sba
D)sba,wba and wac
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
8
For obtaining Silica<5 ppm which of these should be utilized?

A)sba followed by mixed be
B)sba
C)wba sba followed by mixed bed
D)mixed bed
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
9
In which year was the Ferrosand process patented?

A)1960
B)1965
C)1970
D)1975
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
10
What is the permitted concentration of manganese in drinking water?

A)30 g/l
B)40 g/l
C)50 g/l
D)60 g/l
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
11
What is the permitted concentration of arsenic in drinking water?

A)10 g/l
B)20 g/l
C)30 g/l
D)40 g/l
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
12
What is the minimum time of aeration?

A)20 minutes
B)40 minutes
C)60 minutes
D)80 minutes
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
13
What is the tank volume of aeration for water flow of 50m3/h?

A)40 m3
B)50 m3
C)80 m3
D)100 m3
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
14
At what pH should the water be maintained?

A)6.5
B)7.5
C)8.5
D)9
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
15
The aeration system will decrease the redox potential of the water.
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
16
What is the minimum required redox potential of water?

A)100 mv
B)200 mv
C)300 mv
D)400 mv
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
17
Manganese oxidation requires a high oxidation potential.
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
18
What is the desirable bed depth for AFM filtration?

A)1000 mm
B)1200 mm
C)1500 mm
D)1800 mm
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
19
What is the maximum allowable flow for backwash?

A)20 m/hr
B)45 m/hr
C)60 m/hr
D)80 m/hr
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
20
The fluoride concentration for prevention of dental caries is________                

A)1mg/l
B)2mg/l
C)3mg/l
D)4mg/l
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
21
In which process, the fluoride content of water is raised?

A)chlorination
B)fluoridation
C)defluoridation
D)flocculation
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
22
Which of the following is not used as a fluoride compound?

A)sodium fluoride
B)sodium silico fluoride
C)hydrofluosilicic acid
D)sodium fluro carbonate
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
23
Which of the following is the pure compound?

A)sodium fluoride
B)sodium silico fluoride
C)hydrofluosilicic acid
D)sodium fluro carbonate
Unlock Deck
Unlock for access to all 23 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 23 flashcards in this deck.