Deck 18: Single-Phase Transformers Connected in Wye Systems
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
Play
Full screen (f)
Deck 18: Single-Phase Transformers Connected in Wye Systems
1
What are 480-volt systems desired for in many modern installations?
In many modern installations, 480-volt systems are desired for large motor loads such as supermarkets, large retail stores, manufacturing facilities, and so on.
2
How can three-phase capacity be calculated using the line voltages and line current?
Three-phase capacity can be calculated by using the line voltages and line current, as follows: 3-phase KVA = Line E x Line I x 1.73.
3
When is a wye-wye connection unsatisfactory?
The wye-wye connection is unsatisfactory in situations where the secondary load becomes greatly unbalanced. An unbalanced load results in a serious unbalance in the three output voltages of the transformer bank.
4
Where is the 120/208-volt wye system commonly used?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
A wye-wye connected transformer bank cannot be reconnected in an emergency situation by using only two single-phase transformers.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
In a three-phase, four-wire system, the voltage between the neutral and any one of the three line leads on the secondary side is 240 volts.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Many ____________________ are designed for a 277-volt, single-phase line to ground, known as a grounded neutral conductor.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Because the neutral wire is ____________________, it helps protect the three high-voltage primary windings from lightning surges.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
How can voltage unbalancing in the secondary of the transformer bank be nearly eliminated?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Caution: ____________________ all circuits before making connections.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
The wye configuration is sometimes known as a(n) "____________________" connection.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
The total kilovolt-ampere capacity of a wye-wye connected bank is found by adding the individual kVA ratings of the transformer.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Wye-connected transformer banks have only 58% of the line voltage applied to each of the three transformer windings.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Because each of the line wires is connected in ____________________ with one of the transformer windings, the current in each winding is equal to its respective line current.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
When three single-phase coils are connected so that each coil is connected to the beginning of another coil, a simple wye system is formed.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck