Deck 8: Overload Units
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
Play
Full screen (f)
Deck 8: Overload Units
1
What is the best way to assure adequate protection for an overload unit?
The absolute best way to assure adequate protection is to consult the cover of the motor starter, the motor control center, or the manufacturers catalog at the time of installation.These are the instructions given by one manufacturer: when the overload heater size is selected from the table on the inside of the motor starter cover, the nameplate full load amperes current of the motor is used without applying any multipliers.
2
When the melting alloy is a solid, the shaft of the ratchet wheel is held from turning.
True
3
It is important to understand that each different type of overload protection method requires its own _______________.
procedure
4
When the bimetallic strip is heated, the metal with the lower thermal expansion characteristic will become longer, and cause the metal strip to bend.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
The most common type of overload unit is the electronic overload unit.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The overload unit contacts are connected in parallel with the motor starter contactor unit control coil.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Overload units utilize the motor load current to mimic the _______________ characteristics of the motor being protected.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Overload protection is designed with inverse time-delay trip characteristics.This means the ____ the overload current the faster the circuit will open, but a smaller overload would take much longer to open the circuit.
A)average
B)smaller
C)shorter
D)greater
A)average
B)smaller
C)shorter
D)greater
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
What are the three most common types of overload units?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Thermal overload units conduct the motor load current through heater elements.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
A bimetallic strip is used as a(n) _______________ lever.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
Overload units are designed to help energize a motor that is building up excessive heat.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
The absolute best way to assure adequate motor protection is to consult the cover of the motor ____, the motor control center, or the manufacturers catalog at the time of installation.
A)starter
B)compressor
C)gasket
D)thermostat
A)starter
B)compressor
C)gasket
D)thermostat
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
Electronic type of thermal overload units are adjustable for a range of motor load currents, and are set for the full load amperes (FLA) of the specific motor load.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
The _______________ unit is operated by heat developed from the motor load current going through the overload heaters.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Overload units are designed with an inverse time-delay function.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
The three most common types of overload units are the melting alloy (eutectic), bimetallic, and _______________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
The thermal overload unit of the motor starter is located below the ____ contractor.
A)spring
B)magnetic
C)load
D)overhead
A)spring
B)magnetic
C)load
D)overhead
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Electronic motor overload units ____ the motor differently than either the melting alloy or the bimetallic overload units.
A)charge
B)deactivate
C)induce
D)protect
A)charge
B)deactivate
C)induce
D)protect
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
The eutectic alloy in the heater barrel element is a material that goes from a solid state to a liquid state without going through an intermediate ____ stage.
A)gas
B)plasma
C)putty
D)magnetic
A)gas
B)plasma
C)putty
D)magnetic
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck