Deck 11: Wiring Applications

Full screen (f)
exit full mode
Question
A common design practice is to allow a circuit breaker to carry only ____ percent of its continuous current rating.

A) 60
B) 70
C) 80
D) 90
Use Space or
up arrow
down arrow
to flip the card.
Question
When calculating the load, it is common practice to start with the branch circuits and combine their loads at each panel.
Question
A(n) ____ is a place in the wiring system where conductors of opposite polarity make contact.

A) grounded conductor
B) fuse
C) short circuit
D) circuit breaker
Question
A(n) ____ control permits all of the lights or specific groups of lights to be controlled from one location.

A) residential selector
B) universal selector
C) two-way
D) master selector
Question
____ fuses are the type most commonly used in industrial installations.

A) Plug
B) Two-way
C) Replaceable
D) Cartridge
Question
A ground-fault circuit interrupter is a device that senses a small imbalance of current between the ungrounded (hot) conductor and the grounded (neutral) conductor.
Question
Fuses and circuit breakers have ____ current ratings.

A) two
B) three
C) four
D) five
Question
There are three common styles of switches used to control lights including ____.

A) single pole
B) double pole
C) two way
D) grounded
Question
To minimize line drop, electrical services should be installed in a(n) ____ location to minimize the distance to the loads.

A) outdoor
B) top floor
C) central
D) remote
Question
A demand factor is the ratio of the maximum load used at any one time to the total connected load.
Question
At times, lights are controlled by ____ switches and relays.

A) low-voltage
B) inductive
C) high-voltage
D) four-pole
Question
A(n) ____ overcurrent device is a fuse or circuit breaker that opens the circuit much more quickly than the ordinary device does.

A) current-limiting
B) voltage-limiting
C) fast-acting
D) grounding
Question
One of the rules for residential wiring is to install a 200-ampere, three-wire or larger service for a single-family dwelling.
Question
There are ____ general types of circuit breakers.

A) two
B) three
C) four
D) five
Question
Most residential installation circuits are protected against overcurrent by 25-ampere or larger fuses or circuit breakers.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 11: Wiring Applications
1
A common design practice is to allow a circuit breaker to carry only ____ percent of its continuous current rating.

A) 60
B) 70
C) 80
D) 90
C
2
When calculating the load, it is common practice to start with the branch circuits and combine their loads at each panel.
True
3
A(n) ____ is a place in the wiring system where conductors of opposite polarity make contact.

A) grounded conductor
B) fuse
C) short circuit
D) circuit breaker
C
4
A(n) ____ control permits all of the lights or specific groups of lights to be controlled from one location.

A) residential selector
B) universal selector
C) two-way
D) master selector
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
____ fuses are the type most commonly used in industrial installations.

A) Plug
B) Two-way
C) Replaceable
D) Cartridge
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
A ground-fault circuit interrupter is a device that senses a small imbalance of current between the ungrounded (hot) conductor and the grounded (neutral) conductor.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Fuses and circuit breakers have ____ current ratings.

A) two
B) three
C) four
D) five
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
There are three common styles of switches used to control lights including ____.

A) single pole
B) double pole
C) two way
D) grounded
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
To minimize line drop, electrical services should be installed in a(n) ____ location to minimize the distance to the loads.

A) outdoor
B) top floor
C) central
D) remote
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
A demand factor is the ratio of the maximum load used at any one time to the total connected load.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
At times, lights are controlled by ____ switches and relays.

A) low-voltage
B) inductive
C) high-voltage
D) four-pole
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
A(n) ____ overcurrent device is a fuse or circuit breaker that opens the circuit much more quickly than the ordinary device does.

A) current-limiting
B) voltage-limiting
C) fast-acting
D) grounding
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
One of the rules for residential wiring is to install a 200-ampere, three-wire or larger service for a single-family dwelling.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
There are ____ general types of circuit breakers.

A) two
B) three
C) four
D) five
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Most residential installation circuits are protected against overcurrent by 25-ampere or larger fuses or circuit breakers.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.