Deck 3: Grounding and Bonding and the 2011 National Electrical Code, Articles 250, 800, 810, and 820

Full screen (f)
exit full mode
Question
A ground rod connected to the earth protects against ground faults.
Use Space or
up arrow
down arrow
to flip the card.
Question
A metal gas pipe is a suitable ground but only for communication equipment operating at 30V or less.
Question
The ground resistance of a single electrode should have a resistance to earth of not less than 25ohms.
Question
A bonding jumper for a supplemental grounding electrode is required to be not smaller than 14 AWG.
Question
A chassis ground provides safety from ground faults and possible short circuits.
Question
Match between columns
________ Earth ground
Ground fault
________ Earth ground
Grounded conductor
________ Earth ground
Grounding electrode
________ Earth ground
Grounding electrode conductor
________ Earth ground
Grounding electrode systems
________ Earth ground
Equipment grounding conductor
________ Earth ground
Ungrounded conductor
________ Earth ground
Ground
Question
The maximum harmless current intensity for the human body is ______.

A) 5 mA
B) 10 mA
C) 500 mA
D) 1 A
Question
The ________ provides the conductive path to connect the non-current carrying parts of equipment together.

A) Grounded Conductor
B) Chassis Ground
C) Equipment Grounding Conductor
D) All the above
Question
All electrical systems and cables need to maintain at least _________ of separation from the lightning protection system.

A) 2 ft
B) 6 ft
C) 20 ft
D) 50 ft
Question
Not all clamps used for grounding and bonding need to be listed or labled.
Question
Match between columns
________ Accidental electrical connection
Ground fault
________ Accidental electrical connection
Grounded conductor
________ Accidental electrical connection
Grounding electrode
________ Accidental electrical connection
Grounding electrode conductor
________ Accidental electrical connection
Grounding electrode systems
________ Accidental electrical connection
Equipment grounding conductor
________ Accidental electrical connection
Ungrounded conductor
________ Accidental electrical connection
Ground
Question
The following electrodes are permitted for grounding.

A) Interior metal water piping (within 5ft)
B) Metal frame of the building
C) Concrete encased electrode
D) All the above
Question
The length of the primary protection bonding jumper shall not exceed __________.

A) 2 ft
B) 6 ft
C) 12 ft
D) 20 ft
Question
The grounding electrode conductor is typically green in color.
Question
The NEC defines the term ground as "the earth".
Question
Match between columns
________ Interconnects electrodes at a building or structure
Ground fault
________ Interconnects electrodes at a building or structure
Grounded conductor
________ Interconnects electrodes at a building or structure
Grounding electrode
________ Interconnects electrodes at a building or structure
Grounding electrode conductor
________ Interconnects electrodes at a building or structure
Grounding electrode systems
________ Interconnects electrodes at a building or structure
Equipment grounding conductor
________ Interconnects electrodes at a building or structure
Ungrounded conductor
________ Interconnects electrodes at a building or structure
Ground
Question
Which Article of the NEC covers grounding and bonding?

A) Article 250
B) Article 770
C) Article 800
D) Article 810
Question
When running coaxial cable systems, the outer conductive shield must be interrupted as close as possible to the point of entrance to the building.
Question
Alternating current systems less than 50V must always be grounded.
Question
Explain the term ground fault.
Question
Match between columns
________ Circuit conductor that is intentionally grounded
Ground fault
________ Circuit conductor that is intentionally grounded
Grounded conductor
________ Circuit conductor that is intentionally grounded
Grounding electrode
________ Circuit conductor that is intentionally grounded
Grounding electrode conductor
________ Circuit conductor that is intentionally grounded
Grounding electrode systems
________ Circuit conductor that is intentionally grounded
Equipment grounding conductor
________ Circuit conductor that is intentionally grounded
Ungrounded conductor
________ Circuit conductor that is intentionally grounded
Ground
Question
Match between columns
________ Referred to as the hot power line
Ground fault
________ Referred to as the hot power line
Grounded conductor
________ Referred to as the hot power line
Grounding electrode
________ Referred to as the hot power line
Grounding electrode conductor
________ Referred to as the hot power line
Grounding electrode systems
________ Referred to as the hot power line
Equipment grounding conductor
________ Referred to as the hot power line
Ungrounded conductor
________ Referred to as the hot power line
Ground
Question
Match between columns
________ Connects the system neutral and the equipment to the grounding electrode
Ground fault
________ Connects the system neutral and the equipment to the grounding electrode
Grounded conductor
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode conductor
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode systems
________ Connects the system neutral and the equipment to the grounding electrode
Equipment grounding conductor
________ Connects the system neutral and the equipment to the grounding electrode
Ungrounded conductor
________ Connects the system neutral and the equipment to the grounding electrode
Ground
Question
Match between columns
________ Conducting object that makes direct contact with the earth
Ground fault
________ Conducting object that makes direct contact with the earth
Grounded conductor
________ Conducting object that makes direct contact with the earth
Grounding electrode
________ Conducting object that makes direct contact with the earth
Grounding electrode conductor
________ Conducting object that makes direct contact with the earth
Grounding electrode systems
________ Conducting object that makes direct contact with the earth
Equipment grounding conductor
________ Conducting object that makes direct contact with the earth
Ungrounded conductor
________ Conducting object that makes direct contact with the earth
Ground
Question
List three methods permitted for attaching EGC's and bonding jumpers to equipment.
Question
List four suitable grounding electrodes for communication systems _________.
Question
Explain the difference between a main lug panelboard and a main circuit breaker panelboard _______.
Question
Describe the difference between a circuit neutral and a chassis ground.
Question
List the three conditions in which systems operating at 50V or less must be grounded.
Question
Match between columns
________ Conductive path to metallic parts of equipment
Ground fault
________ Conductive path to metallic parts of equipment
Grounded conductor
________ Conductive path to metallic parts of equipment
Grounding electrode
________ Conductive path to metallic parts of equipment
Grounding electrode conductor
________ Conductive path to metallic parts of equipment
Grounding electrode systems
________ Conductive path to metallic parts of equipment
Equipment grounding conductor
________ Conductive path to metallic parts of equipment
Ungrounded conductor
________ Conductive path to metallic parts of equipment
Ground
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/30
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 3: Grounding and Bonding and the 2011 National Electrical Code, Articles 250, 800, 810, and 820
1
A ground rod connected to the earth protects against ground faults.
False
2
A metal gas pipe is a suitable ground but only for communication equipment operating at 30V or less.
False
3
The ground resistance of a single electrode should have a resistance to earth of not less than 25ohms.
True
4
A bonding jumper for a supplemental grounding electrode is required to be not smaller than 14 AWG.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
5
A chassis ground provides safety from ground faults and possible short circuits.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
6
Match between columns
________ Earth ground
Ground fault
________ Earth ground
Grounded conductor
________ Earth ground
Grounding electrode
________ Earth ground
Grounding electrode conductor
________ Earth ground
Grounding electrode systems
________ Earth ground
Equipment grounding conductor
________ Earth ground
Ungrounded conductor
________ Earth ground
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
7
The maximum harmless current intensity for the human body is ______.

A) 5 mA
B) 10 mA
C) 500 mA
D) 1 A
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
8
The ________ provides the conductive path to connect the non-current carrying parts of equipment together.

A) Grounded Conductor
B) Chassis Ground
C) Equipment Grounding Conductor
D) All the above
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
9
All electrical systems and cables need to maintain at least _________ of separation from the lightning protection system.

A) 2 ft
B) 6 ft
C) 20 ft
D) 50 ft
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
10
Not all clamps used for grounding and bonding need to be listed or labled.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
11
Match between columns
________ Accidental electrical connection
Ground fault
________ Accidental electrical connection
Grounded conductor
________ Accidental electrical connection
Grounding electrode
________ Accidental electrical connection
Grounding electrode conductor
________ Accidental electrical connection
Grounding electrode systems
________ Accidental electrical connection
Equipment grounding conductor
________ Accidental electrical connection
Ungrounded conductor
________ Accidental electrical connection
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
12
The following electrodes are permitted for grounding.

A) Interior metal water piping (within 5ft)
B) Metal frame of the building
C) Concrete encased electrode
D) All the above
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
13
The length of the primary protection bonding jumper shall not exceed __________.

A) 2 ft
B) 6 ft
C) 12 ft
D) 20 ft
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
14
The grounding electrode conductor is typically green in color.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
15
The NEC defines the term ground as "the earth".
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
16
Match between columns
________ Interconnects electrodes at a building or structure
Ground fault
________ Interconnects electrodes at a building or structure
Grounded conductor
________ Interconnects electrodes at a building or structure
Grounding electrode
________ Interconnects electrodes at a building or structure
Grounding electrode conductor
________ Interconnects electrodes at a building or structure
Grounding electrode systems
________ Interconnects electrodes at a building or structure
Equipment grounding conductor
________ Interconnects electrodes at a building or structure
Ungrounded conductor
________ Interconnects electrodes at a building or structure
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
17
Which Article of the NEC covers grounding and bonding?

A) Article 250
B) Article 770
C) Article 800
D) Article 810
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
18
When running coaxial cable systems, the outer conductive shield must be interrupted as close as possible to the point of entrance to the building.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
19
Alternating current systems less than 50V must always be grounded.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
20
Explain the term ground fault.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
21
Match between columns
________ Circuit conductor that is intentionally grounded
Ground fault
________ Circuit conductor that is intentionally grounded
Grounded conductor
________ Circuit conductor that is intentionally grounded
Grounding electrode
________ Circuit conductor that is intentionally grounded
Grounding electrode conductor
________ Circuit conductor that is intentionally grounded
Grounding electrode systems
________ Circuit conductor that is intentionally grounded
Equipment grounding conductor
________ Circuit conductor that is intentionally grounded
Ungrounded conductor
________ Circuit conductor that is intentionally grounded
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
22
Match between columns
________ Referred to as the hot power line
Ground fault
________ Referred to as the hot power line
Grounded conductor
________ Referred to as the hot power line
Grounding electrode
________ Referred to as the hot power line
Grounding electrode conductor
________ Referred to as the hot power line
Grounding electrode systems
________ Referred to as the hot power line
Equipment grounding conductor
________ Referred to as the hot power line
Ungrounded conductor
________ Referred to as the hot power line
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
23
Match between columns
________ Connects the system neutral and the equipment to the grounding electrode
Ground fault
________ Connects the system neutral and the equipment to the grounding electrode
Grounded conductor
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode conductor
________ Connects the system neutral and the equipment to the grounding electrode
Grounding electrode systems
________ Connects the system neutral and the equipment to the grounding electrode
Equipment grounding conductor
________ Connects the system neutral and the equipment to the grounding electrode
Ungrounded conductor
________ Connects the system neutral and the equipment to the grounding electrode
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
24
Match between columns
________ Conducting object that makes direct contact with the earth
Ground fault
________ Conducting object that makes direct contact with the earth
Grounded conductor
________ Conducting object that makes direct contact with the earth
Grounding electrode
________ Conducting object that makes direct contact with the earth
Grounding electrode conductor
________ Conducting object that makes direct contact with the earth
Grounding electrode systems
________ Conducting object that makes direct contact with the earth
Equipment grounding conductor
________ Conducting object that makes direct contact with the earth
Ungrounded conductor
________ Conducting object that makes direct contact with the earth
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
25
List three methods permitted for attaching EGC's and bonding jumpers to equipment.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
26
List four suitable grounding electrodes for communication systems _________.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
27
Explain the difference between a main lug panelboard and a main circuit breaker panelboard _______.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
28
Describe the difference between a circuit neutral and a chassis ground.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
29
List the three conditions in which systems operating at 50V or less must be grounded.
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
30
Match between columns
________ Conductive path to metallic parts of equipment
Ground fault
________ Conductive path to metallic parts of equipment
Grounded conductor
________ Conductive path to metallic parts of equipment
Grounding electrode
________ Conductive path to metallic parts of equipment
Grounding electrode conductor
________ Conductive path to metallic parts of equipment
Grounding electrode systems
________ Conductive path to metallic parts of equipment
Equipment grounding conductor
________ Conductive path to metallic parts of equipment
Ungrounded conductor
________ Conductive path to metallic parts of equipment
Ground
Unlock Deck
Unlock for access to all 30 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 30 flashcards in this deck.