Deck 13: Heating Control Devices

Full screen (f)
exit full mode
Question
The basic control cycle of a gas heating appliance is initiated when a switch, usually a ____________________, closes to call for heat.
Use Space or
up arrow
down arrow
to flip the card.
Question
The ____________________ is the heart of an oil burner control system and supervises the operation of the oil burner.
Question
The ____________________ fan switch is nothing more than a thermostat that closes on a rise in temperature to start the fan motor when the furnace can supply warm air to the structure.
Question
In a(n) ____________________ heating system, a call for heat completes the heating control circuit, starting a chain reaction that results in lighting a burner.
Question
____________________ systems use a spark igniter (direct spark ignition) or a silicon carbide igniter (hot surface ignition) to light the main gas burner directly.
Question
Steam is the most popular method of transferring heat from an appliance to a structure.
Question
How many contacts can a sequencer have? Do they close in unison?
Question
What are the two main types of hot water heating units used to supply heat to a conditioned space?
Question
The ____________________ pilot burns only when there is a call for heating and remains off when there is no call for heat.
Question
Thermostats that are immersed in water are sometimes called ____________________.
Question
What do forced-air electric furnaces use to provide heat to a conditioned area?
Question
In the basic warm-air furnace, many controls that are applicable to warm-air furnaces depend on the type of energy that is being used to supply the heat to the structure.
Question
In all types of forced-air heating equipment, there must be some method of controlling the fan motor so that the warm air is delivered to the conditioned space at the correct temperature.
Question
The intermittent pilot control system must only light the pilot.
Question
____________________ on heating appliances are basically thermostats that open when an unsafe condition exists in the furnace, such as high furnace temperatures.
Question
There are several types of fan switches used in industry.
Question
The basic heating appliance used in the heating and cooling industry usually heats air or water or produces steam.
Question
A stack switch is a heat-actuated control that uses the stack temperature to indicate that the oil burner has or has not established a flame.
Question
Limit switches are used in case of ____________________, which is flame extending outside the combustion chamber or heat exchanger.
Question
How do hydronic heating systems circulate water throughout a structure?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 13: Heating Control Devices
1
The basic control cycle of a gas heating appliance is initiated when a switch, usually a ____________________, closes to call for heat.
thermostat
2
The ____________________ is the heart of an oil burner control system and supervises the operation of the oil burner.
primary control
3
The ____________________ fan switch is nothing more than a thermostat that closes on a rise in temperature to start the fan motor when the furnace can supply warm air to the structure.
temperature-controlled,temperature controlled
4
In a(n) ____________________ heating system, a call for heat completes the heating control circuit, starting a chain reaction that results in lighting a burner.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
____________________ systems use a spark igniter (direct spark ignition) or a silicon carbide igniter (hot surface ignition) to light the main gas burner directly.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Steam is the most popular method of transferring heat from an appliance to a structure.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
How many contacts can a sequencer have? Do they close in unison?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
What are the two main types of hot water heating units used to supply heat to a conditioned space?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
The ____________________ pilot burns only when there is a call for heating and remains off when there is no call for heat.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
Thermostats that are immersed in water are sometimes called ____________________.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
What do forced-air electric furnaces use to provide heat to a conditioned area?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
In the basic warm-air furnace, many controls that are applicable to warm-air furnaces depend on the type of energy that is being used to supply the heat to the structure.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
In all types of forced-air heating equipment, there must be some method of controlling the fan motor so that the warm air is delivered to the conditioned space at the correct temperature.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
The intermittent pilot control system must only light the pilot.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
____________________ on heating appliances are basically thermostats that open when an unsafe condition exists in the furnace, such as high furnace temperatures.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
There are several types of fan switches used in industry.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
The basic heating appliance used in the heating and cooling industry usually heats air or water or produces steam.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
A stack switch is a heat-actuated control that uses the stack temperature to indicate that the oil burner has or has not established a flame.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Limit switches are used in case of ____________________, which is flame extending outside the combustion chamber or heat exchanger.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
How do hydronic heating systems circulate water throughout a structure?