Deck 21: Alarm and Event Programming
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
Play
Full screen (f)
Deck 21: Alarm and Event Programming
1
Almost all power supplies are shipped from the manufacturer with the voltage setting in the HIGH voltage (240 V) position.
True
2
Explain what to check if an output module LED illuminates but the device does not energize.
1. Wiring to the output device.
2. Operation of the output device.
3. Proper potential to the output device.
4. Output device wired to correct output module and proper terminal.
2. Operation of the output device.
3. Proper potential to the output device.
4. Output device wired to correct output module and proper terminal.
3
A(n) ____________________ ON instruction intensifies or goes to reverse video when the input device is ON, or closed.
EXAMINE
4
To be a successful troubleshooter, the technician must use a(n) ____________________ approach.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
At the end of the start-up procedure, what are you looking for after you apply power?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Each time an input device is closed, the corresponding LED on the input module should illuminate.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
There are three methods used to test output devices.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
The first step in the start-up procedure is to check all power and communication cables to ensure that the connector pins are straight, and not bent or pulled out.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
For outputs that can be ____________________, be sure equipment is in the start-up position, is properly lubricated, and is ready to run.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Explain a method of testing inputs other than using EXAMINE commands.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Explain what must be checked even before the start-up procedure is undertaken.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
The electrician and/or technician should be aware of how the system normally functions if he or she expects to successfully troubleshoot the system.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
During start-up, you should ensure that all ____________________ are securely held in the I/O rack, and that field wiring arms (if applicable) are fully seated and locked.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Careful start-up procedures are necessary to prevent damage to the driven equipment and the programmable controller system, or, more importantly, ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Explain why you must use a high-impedance meter to test voltage readings on PLC input circuits.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck