Deck 22: Plumbing Codes: Fuel Gas Piping

Full screen (f)
exit full mode
Question
What should the spacing of supports be for a 1 1/4-inch steel pipe?

A)6 feet
B)8 feet
C)10 feet
D)12 feet
Use Space or
up arrow
down arrow
to flip the card.
Question
What should the spacing of supports be for a 1-inch or larger piece of smooth wall tubing?

A)6 feet
B)every floor level
C)5 feet
D)4 feet
Question
Corrugated stainless steel tubing (CSST)is ideal for use as a bonding point.
Question
The NFGC allows for engineered designed systems as long as which of the following conditions are met?

A)the piping is welded
B)the piping is located in a ventilated chase
C)the piping is a temporary installation for building under construction
D)all of the above
Question
Of the following fuel gas code exceptions, which of the following is not listed as excluded in the UPC?

A)construction of appliances
B)LP-gas piping
C)liquified natural gas installations
D)petroleum refineries
Question
Which of the following settings would most likely require a backup fuel supply?

A)restaurant
B)residence
C)hospital
D)campground
Question
What should the spacing of supports be for a 1/2 inch steel pipe?

A)6 feet
B)8 feet
C)10 feet
D)12 feet
Question
All three codes, the NFPA, NFGC, and UPC, limit gas system pressures to:

A)5 psi or less
B)10 psi or less
C)2 psi or less
D)12 psi or less
Question
In what year did the American Gas Association publish the first edition of its requirements for house piping and appliance installation?

A)1928
B)1925
C)1931
D)1913
Question
The International Fuel Gas Code (IFGC)and the Uniform Plumbing Code (UPC)both reference the National Fuel Gas Code.
Question
What should the spacing of supports be for a 1/2 inch piece of smooth wall tubing?

A)6 feet
B)8 feet
C)5 feet
D)4 feet
Question
The use of gas meters is at the discretion of the building owner.
Question
The National Fuel Gas Code (NFGC)was first published in what year?

A)1965
B)1974
C)1981
D)1979
Question
In what year did the NFPA form a subcommittee to prepare a fire protection code for city gas installations?

A)1920
B)1896
C)1913
D)1936
Question
Of the following fuel gas code exceptions, which of the following is not listed as excluded in the UPC?

A)installation of LP gas systems for railroad switch heating
B)LP-gas piping
C)liquified natural gas installations
D)fuel gas systems using hydrogen
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Plumbing Codes: Fuel Gas Piping
1
What should the spacing of supports be for a 1 1/4-inch steel pipe?

A)6 feet
B)8 feet
C)10 feet
D)12 feet
C
2
What should the spacing of supports be for a 1-inch or larger piece of smooth wall tubing?

A)6 feet
B)every floor level
C)5 feet
D)4 feet
B
3
Corrugated stainless steel tubing (CSST)is ideal for use as a bonding point.
False
4
The NFGC allows for engineered designed systems as long as which of the following conditions are met?

A)the piping is welded
B)the piping is located in a ventilated chase
C)the piping is a temporary installation for building under construction
D)all of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Of the following fuel gas code exceptions, which of the following is not listed as excluded in the UPC?

A)construction of appliances
B)LP-gas piping
C)liquified natural gas installations
D)petroleum refineries
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following settings would most likely require a backup fuel supply?

A)restaurant
B)residence
C)hospital
D)campground
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
What should the spacing of supports be for a 1/2 inch steel pipe?

A)6 feet
B)8 feet
C)10 feet
D)12 feet
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
All three codes, the NFPA, NFGC, and UPC, limit gas system pressures to:

A)5 psi or less
B)10 psi or less
C)2 psi or less
D)12 psi or less
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
In what year did the American Gas Association publish the first edition of its requirements for house piping and appliance installation?

A)1928
B)1925
C)1931
D)1913
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
The International Fuel Gas Code (IFGC)and the Uniform Plumbing Code (UPC)both reference the National Fuel Gas Code.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
What should the spacing of supports be for a 1/2 inch piece of smooth wall tubing?

A)6 feet
B)8 feet
C)5 feet
D)4 feet
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
The use of gas meters is at the discretion of the building owner.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
The National Fuel Gas Code (NFGC)was first published in what year?

A)1965
B)1974
C)1981
D)1979
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
In what year did the NFPA form a subcommittee to prepare a fire protection code for city gas installations?

A)1920
B)1896
C)1913
D)1936
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Of the following fuel gas code exceptions, which of the following is not listed as excluded in the UPC?

A)installation of LP gas systems for railroad switch heating
B)LP-gas piping
C)liquified natural gas installations
D)fuel gas systems using hydrogen
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.