Deck 22: Installing Control Systems

Full screen (f)
exit full mode
Question
When connecting a circuit, what are some actions that can be taken to aid in the identification of all the components?
Use Space or
up arrow
down arrow
to flip the card.
Question
Figure 22-1
Figure 22-1   In the accompanying figure, two float switches are necessary in this circuit because the tank is to be ____________________.<div style=padding-top: 35px>
In the accompanying figure, two float switches are necessary in this circuit because the tank is to be ____________________.
Question
One of the methods for installing control systems involves using a(n) ____________________ to terminate the different control components.
Question
The point-to-point method generally results in a saving of wire.
Question
Why are wiring drawings sometimes misleading?
Question
In the above figure, the normally open contact of float FS1 is used to prevent the ____________________ from energizing unless the tank is full of water.
Question
Although connecting components to a terminal strip generally involves using a greater amount of wire, it can be the less expensive method when it is necessary to ____________________ the circuit.
Question
Figure 22-1
Figure 22-1   In the accompanying figure, what do float switches FS1 and FS2 do?<div style=padding-top: 35px>
In the accompanying figure, what do float switches FS1 and FS2 do?
Question
Components such as float switches and pressure switches will generally be located on tanks.
Question
In the ____________________ method, components are connected from one point to another depending on the proximity of one component to another.
Question
Connecting components to a terminal strip is the more expensive method when it is necessary to troubleshoot the circuit.
Question
In the point-to-point method, the connections made inside the MCC are shown with solid lines.
Question
In the accompanying figure, what happens when the water level begins to rise?
Question
In the accompanying figure, what happens when the water level drops sufficiently?
Question
When making connections, wire numbers should be placed on the wire at any point of termination.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Installing Control Systems
1
When connecting a circuit, what are some actions that can be taken to aid in the identification of all the components?
When making connections, wire numbers should be placed on the wire at any point of termination. This greatly aids in troubleshooting the circuit. Each component should also be labeled with a tag to identify the component.
2
Figure 22-1
Figure 22-1   In the accompanying figure, two float switches are necessary in this circuit because the tank is to be ____________________.
In the accompanying figure, two float switches are necessary in this circuit because the tank is to be ____________________.
pressurized
3
One of the methods for installing control systems involves using a(n) ____________________ to terminate the different control components.
terminal strip
4
The point-to-point method generally results in a saving of wire.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Why are wiring drawings sometimes misleading?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
In the above figure, the normally open contact of float FS1 is used to prevent the ____________________ from energizing unless the tank is full of water.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Although connecting components to a terminal strip generally involves using a greater amount of wire, it can be the less expensive method when it is necessary to ____________________ the circuit.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Figure 22-1
Figure 22-1   In the accompanying figure, what do float switches FS1 and FS2 do?
In the accompanying figure, what do float switches FS1 and FS2 do?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
Components such as float switches and pressure switches will generally be located on tanks.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
In the ____________________ method, components are connected from one point to another depending on the proximity of one component to another.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
Connecting components to a terminal strip is the more expensive method when it is necessary to troubleshoot the circuit.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
In the point-to-point method, the connections made inside the MCC are shown with solid lines.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
In the accompanying figure, what happens when the water level begins to rise?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
In the accompanying figure, what happens when the water level drops sufficiently?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
When making connections, wire numbers should be placed on the wire at any point of termination.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck