Deck 20: Checking Out and Troubleshooting Electrical Wiring Systems

Full screen (f)
exit full mode
Question
In a sub-panel, a green bonding screw provided by the panel manufacturer must be installed to electrically bond the grounded feeder conductor and the equipment-grounding conductors to the panel enclosure.
Use Space or
up arrow
down arrow
to flip the card.
Question
When holes are bored through wood framing members, they must be at least __________ inches from the nearest edge of the wood member.

A) 1
B) 1-1/8
C) 1-1/4
D) 1-1/2
Question
Residential electrical systems may be grounded using only the metal water pipe system and do not need a supplemental grounding electrode.
Question
Which of the following is not a NEC requirement for minimum clearance of a lighting fixture from the storage space in clothes closets?

A) 12" for surface incandescent or LED fixtures
B) 6" for recessed incandescent or LED fixtures
C) 12" for surface fluorescent fixtures
D) 6" for recessed fluorescent fixtures
Question
Receptacle outlets in habitable rooms must be installed so that no point measured horizontally along the floor line in any wall space in more than __________ feet from a receptacle outlet.

A) 2
B) 6
C) 10
D) 12
Question
A(n) __________ is an unintended low-resistance path through which current flows around, rather than along, a circuit's intended current path.

A) grounded circuit
B) open circuit
C) short circuit
D) grounding circuit
Question
GFCI protection is not required for 125 volt, 15- or 20-ampere receptacles located __________.

A) in bathrooms
B) in finished basements
C) in garages
D) outdoors
Question
The rating of the __________ determines the rating of a branch or feeder circuit.

A) fuse or circuit breaker
B) conductor
C) receptacle
D) main panel
Question
A continuity tester can be used to find short circuits, ground faults, and open circuits in de-energized circuits.
Question
The minimum length of free conductor at all boxes must be at least __________ inches.

A) 3
B) 6
C) 8
D) 12
Question
Outdoor receptacles must be installed __________.

A) only at the front of the dwelling
B) every 12 feet along the wall line
C) no more than 6.5 feet above grade
D) on each side of the dwelling
Question
According to the NEC, all work spaces must be provided with illumination.
Question
At kitchen countertops, receptacle outlets must be installed so that no point along the wall line is more than __________ feet, measured horizontally, from a receptacle outlet in that space.

A) 2
B) 6
C) 10
D) 12
Question
When there is a short in a branch circuit, a high circuit resistance develops that results in low amounts of current flowing on the circuit.
Question
The minimum size of service disconnect for a single-family dwelling unit permitted by the NEC is __________ amperes.

A) 60
B) 75
C) 100
D) 150
Question
In residential applications, Type NM cable is permitted to pass through environmental air handling spaces perpendicular to the long dimension of the space.
Question
According to the NEC, lighting fixtures must be installed in clothes closets.
Question
All branch circuits supplying 125-volt, 15- and 20-ampere outlets and devices in residential kitchens, family rooms, living rooms, dining rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms must be protected by a(n) __________

A) fuse
B) circuit breaker
C) GFCI device
D) AFCI device
Question
A(n) __________ is a circuit that is energized but does not allow useful current to flow on the circuit because of a break in the current path.

A) grounded circuit
B) short circuit
C) ground fault
D) open circuit
Question
At least __________ 20-ampere small appliance branch circuits are (is) required to serve kitchen countertop surfaces.

A) 1
B) 2
C) 3
D) No minimum number of circuits required
Question
When the white grounded circuit conductor is connected to the silver screw on a receptacle and the "hot" ungrounded conductor is connected to the brass screw on the receptacle, you have proper receptacle __________.

A) troubleshooting
B) grounding
C) polarity
D) timing
Question
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the ungrounded conductor connection (short slot) to the grounding conductor connection (U-shaped slot).
Question
When testing a "live" 50-ampere, 125/250-volt range receptacle using a voltage tester, you should get a 240-volt reading when measuring from the grounded conductor connection (W slot) to either ungrounded conductor connection (X or Y slot).
Question
A(n) _________________________ is an unintended low-resistance path in an electrical circuit through which some current flows to ground using a pathway other than the intended pathway.
Question
The house electrical system may be grounded using a metal water pipe in direct contact with the earth for at least __________ feet.

A) 5
B) 10
C) 12
D) 20
Question
An electrician is testing a 15-ampere, 125-volt rated duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 120 volts between the grounded slot and the grounding slot.The likely cause is __________.

A) an open equipment grounding path
B) a short circuit in the cable feeding the receptacle
C) an open grounded circuit conductor
D) reversed polarity at the receptacle
Question
An electrician is testing a 20-ampere, 125-volt duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 0 volts between the ungrounded slot and the grounding slot.The likely cause is __________.

A) an open equipment-grounding path
B) reversed polarity at the receptacle
C) an open grounded circuit conductor
D) a short circuit in the cable feeding the receptacle
Question
Regular fluorescent ballasts are designed to light fluorescent lamps in an ambient temperature of __________ degrees F or higher.

A) 25
B) 40
C) 50
D) 63
Question
The NEC requires a minimum of __________-20 ampere bathroom branch circuit in a dwelling unit.

A) 1
B) 2
C) 3
D) 4
Question
An electrician tests a three-way switching circuit.The lighting load can be turned OFF and then ON at each of the three-way switch locations.However, when one three-way switch toggle is left in the up position, toggling the other three-way switch does not cause the lighting load to come on.The likely cause is __________.

A) an open grounding path
B) an open grounded path
C) the traveler wires are incorrectly connected to the traveler terminals on the switch
D) there is no electrical power at the switch
Question
Type NM cable must be secured no more than ____________________ inches from each single-gang nonmetallic device box.
Question
An electrician tests a 30-ampere, 250-volt dryer receptacle with a voltage tester.The tester indicates 120 volts between the X and Y slots.The tester also indicates 240 volts between the X and W slots.The tester also indicates 0 volts between the Y and the grounding slot.The likely cause is __________.

A) an open grounding path
B) the wires are reversed between the W and the Y slots
C) the wires are reversed between the X and the Y slots
D) an open grounded conductor
Question
If a receptacle is wired correctly, the short slot is always the ____________________ slot.
Question
A feed-though condition may cause false readings during circuit testing and can happen when a load is still connected to the circuit being tested.
Question
Recessed lighting fixtures installed in insulated ceilings so that the insulation is covering the fixture must be labeled ____________________.
Question
Explain "feed through" as it applies to using a continuity tester when testing a lighting circuit.
Question
NEC Table __________ contains the requirements for direct burial of conductors and raceways.

A) 110.26
B) 220.12
C) 300.5
D) 310.15(B)(16)
Question
An electrician is testing a circuit where a single-pole switch controls an LED lighting fixture in a bedroom.When the single-pole switch is toggled ON, the lighting fixture does not come on.Which of the following items could not be a cause for this?

A) there is an open grounding path
B) the circuit breaker protecting the circuit is off
C) there are no lamps installed in the lighting fixture
D) the connections to the lighting fixture are not making a good connection
Question
In the NEC, Article __________ contains requirements for grounding and bonding residential electrical systems.

A) 200
B) 230
C) 240
D) 250
Question
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the grounded conductor connection (long slot) to the grounding conductor connection (U-shaped slot).
Question
Describe what a circuit tracer does and when it is used.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/41
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 20: Checking Out and Troubleshooting Electrical Wiring Systems
1
In a sub-panel, a green bonding screw provided by the panel manufacturer must be installed to electrically bond the grounded feeder conductor and the equipment-grounding conductors to the panel enclosure.
False
Only required in main panels.
2
When holes are bored through wood framing members, they must be at least __________ inches from the nearest edge of the wood member.

A) 1
B) 1-1/8
C) 1-1/4
D) 1-1/2
C
3
Residential electrical systems may be grounded using only the metal water pipe system and do not need a supplemental grounding electrode.
False
4
Which of the following is not a NEC requirement for minimum clearance of a lighting fixture from the storage space in clothes closets?

A) 12" for surface incandescent or LED fixtures
B) 6" for recessed incandescent or LED fixtures
C) 12" for surface fluorescent fixtures
D) 6" for recessed fluorescent fixtures
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
5
Receptacle outlets in habitable rooms must be installed so that no point measured horizontally along the floor line in any wall space in more than __________ feet from a receptacle outlet.

A) 2
B) 6
C) 10
D) 12
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
6
A(n) __________ is an unintended low-resistance path through which current flows around, rather than along, a circuit's intended current path.

A) grounded circuit
B) open circuit
C) short circuit
D) grounding circuit
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
7
GFCI protection is not required for 125 volt, 15- or 20-ampere receptacles located __________.

A) in bathrooms
B) in finished basements
C) in garages
D) outdoors
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
8
The rating of the __________ determines the rating of a branch or feeder circuit.

A) fuse or circuit breaker
B) conductor
C) receptacle
D) main panel
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
9
A continuity tester can be used to find short circuits, ground faults, and open circuits in de-energized circuits.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
10
The minimum length of free conductor at all boxes must be at least __________ inches.

A) 3
B) 6
C) 8
D) 12
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
11
Outdoor receptacles must be installed __________.

A) only at the front of the dwelling
B) every 12 feet along the wall line
C) no more than 6.5 feet above grade
D) on each side of the dwelling
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
12
According to the NEC, all work spaces must be provided with illumination.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
13
At kitchen countertops, receptacle outlets must be installed so that no point along the wall line is more than __________ feet, measured horizontally, from a receptacle outlet in that space.

A) 2
B) 6
C) 10
D) 12
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
14
When there is a short in a branch circuit, a high circuit resistance develops that results in low amounts of current flowing on the circuit.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
15
The minimum size of service disconnect for a single-family dwelling unit permitted by the NEC is __________ amperes.

A) 60
B) 75
C) 100
D) 150
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
16
In residential applications, Type NM cable is permitted to pass through environmental air handling spaces perpendicular to the long dimension of the space.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
17
According to the NEC, lighting fixtures must be installed in clothes closets.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
18
All branch circuits supplying 125-volt, 15- and 20-ampere outlets and devices in residential kitchens, family rooms, living rooms, dining rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, or similar rooms must be protected by a(n) __________

A) fuse
B) circuit breaker
C) GFCI device
D) AFCI device
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
19
A(n) __________ is a circuit that is energized but does not allow useful current to flow on the circuit because of a break in the current path.

A) grounded circuit
B) short circuit
C) ground fault
D) open circuit
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
20
At least __________ 20-ampere small appliance branch circuits are (is) required to serve kitchen countertop surfaces.

A) 1
B) 2
C) 3
D) No minimum number of circuits required
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
21
When the white grounded circuit conductor is connected to the silver screw on a receptacle and the "hot" ungrounded conductor is connected to the brass screw on the receptacle, you have proper receptacle __________.

A) troubleshooting
B) grounding
C) polarity
D) timing
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
22
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the ungrounded conductor connection (short slot) to the grounding conductor connection (U-shaped slot).
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
23
When testing a "live" 50-ampere, 125/250-volt range receptacle using a voltage tester, you should get a 240-volt reading when measuring from the grounded conductor connection (W slot) to either ungrounded conductor connection (X or Y slot).
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
24
A(n) _________________________ is an unintended low-resistance path in an electrical circuit through which some current flows to ground using a pathway other than the intended pathway.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
25
The house electrical system may be grounded using a metal water pipe in direct contact with the earth for at least __________ feet.

A) 5
B) 10
C) 12
D) 20
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
26
An electrician is testing a 15-ampere, 125-volt rated duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 120 volts between the grounded slot and the grounding slot.The likely cause is __________.

A) an open equipment grounding path
B) a short circuit in the cable feeding the receptacle
C) an open grounded circuit conductor
D) reversed polarity at the receptacle
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
27
An electrician is testing a 20-ampere, 125-volt duplex receptacle with a voltage tester.The tester indicates 120 volts between the ungrounded slot and the grounded slot.The tester also indicates 0 volts between the ungrounded slot and the grounding slot.The likely cause is __________.

A) an open equipment-grounding path
B) reversed polarity at the receptacle
C) an open grounded circuit conductor
D) a short circuit in the cable feeding the receptacle
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
28
Regular fluorescent ballasts are designed to light fluorescent lamps in an ambient temperature of __________ degrees F or higher.

A) 25
B) 40
C) 50
D) 63
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
29
The NEC requires a minimum of __________-20 ampere bathroom branch circuit in a dwelling unit.

A) 1
B) 2
C) 3
D) 4
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
30
An electrician tests a three-way switching circuit.The lighting load can be turned OFF and then ON at each of the three-way switch locations.However, when one three-way switch toggle is left in the up position, toggling the other three-way switch does not cause the lighting load to come on.The likely cause is __________.

A) an open grounding path
B) an open grounded path
C) the traveler wires are incorrectly connected to the traveler terminals on the switch
D) there is no electrical power at the switch
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
31
Type NM cable must be secured no more than ____________________ inches from each single-gang nonmetallic device box.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
32
An electrician tests a 30-ampere, 250-volt dryer receptacle with a voltage tester.The tester indicates 120 volts between the X and Y slots.The tester also indicates 240 volts between the X and W slots.The tester also indicates 0 volts between the Y and the grounding slot.The likely cause is __________.

A) an open grounding path
B) the wires are reversed between the W and the Y slots
C) the wires are reversed between the X and the Y slots
D) an open grounded conductor
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
33
If a receptacle is wired correctly, the short slot is always the ____________________ slot.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
34
A feed-though condition may cause false readings during circuit testing and can happen when a load is still connected to the circuit being tested.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
35
Recessed lighting fixtures installed in insulated ceilings so that the insulation is covering the fixture must be labeled ____________________.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
36
Explain "feed through" as it applies to using a continuity tester when testing a lighting circuit.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
37
NEC Table __________ contains the requirements for direct burial of conductors and raceways.

A) 110.26
B) 220.12
C) 300.5
D) 310.15(B)(16)
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
38
An electrician is testing a circuit where a single-pole switch controls an LED lighting fixture in a bedroom.When the single-pole switch is toggled ON, the lighting fixture does not come on.Which of the following items could not be a cause for this?

A) there is an open grounding path
B) the circuit breaker protecting the circuit is off
C) there are no lamps installed in the lighting fixture
D) the connections to the lighting fixture are not making a good connection
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
39
In the NEC, Article __________ contains requirements for grounding and bonding residential electrical systems.

A) 200
B) 230
C) 240
D) 250
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
40
When testing a "live" 120-volt receptacle using a voltage tester, you should get a 120-volt reading when measuring from the grounded conductor connection (long slot) to the grounding conductor connection (U-shaped slot).
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
41
Describe what a circuit tracer does and when it is used.
Unlock Deck
Unlock for access to all 41 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 41 flashcards in this deck.