Deck 11: Load Calculations

Full screen (f)
exit full mode
Question
When calculating load, the ____ can be omitted, as long as they are never energized simultaneously.

A) smallest branch circuits
B) smaller of two (or more) noncoincident loads
C) branch circuits containing the kitchen and laundry room
D) larger of two (or more) branch circuits
Use Space or
up arrow
down arrow
to flip the card.
Question
No more than ____ disconnects per service can be grouped in one location.

A) two
B) four
C) six
D) eight
Question
Derating is allowed for a total of four (or more) ____.

A) fastened-in-place appliances
B) branch circuits
C) kitchen receptacles
D) basement receptacles
Question
All 15- or 20-ampere general-use receptacle outlets (except for small-appliance and laundry) are considered part of the ____.

A) main branch
B) central service
C) general lighting load
D) general service
Question
The term appliance designates ____ equipment installed as a unit to perform specific function(s).

A) laundry
B) kitchen
C) compliance
D) utilization
Question
In a multiple-occupancy building, each occupant must have access to the unit's ____.

A) main feeder line
B) service meter
C) fuse box
D) service disconnecting means
Question
A load calculation on an individual unit in a multifamily dwelling must be calculated in accordance with one of the ____.

A) multi-family dwelling load-calculation methods
B) multi-family dwelling load-calculation methods and divided by the number of units per floor
C) one-family dwelling load-calculation methods
D) one-family dwelling load-calculation methods and multiplied by the number of units per floor
Question
When calculating load, household cooking appliances rated over ____ kW should be included.

A) 1.25
B) 1.50
C) 1.75
D) 10
Question
When calculating appliance load in a one-family dwelling, ____ should be used.

A) demand factors
B) compliance ratings
C) BTUs
D) nameplate ratings
Question
The service disconnecting means for a standard load calculation for a single unit of a multifamily dwelling must have a rating of at least ____.

A) the calculated load
B) the load for a single unit
C) one quarter the total load
D) one half the total load
Question
A heat pump with supplementary heat is ____.

A) considered a coincident load
B) not considered a noncoincident load
C) sometimes considered a coincident load
D) sometimes considered a noncoincident load
Question
Each laundry branch circuit is calculated at no less than ____ volt-amperes.

A) 1000
B) 1100
C) 1200
D) 1500
Question
A clothes dryer neutral load on a feeder is calculated at ____%.

A) 50
B) 60
C) 70
D) 80
Question
Electric heating loads (including associated motors) are calculated at ____% of the total connected load.

A) 75
B) 100
C) 125
D) 150
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 11: Load Calculations
1
When calculating load, the ____ can be omitted, as long as they are never energized simultaneously.

A) smallest branch circuits
B) smaller of two (or more) noncoincident loads
C) branch circuits containing the kitchen and laundry room
D) larger of two (or more) branch circuits
B
2
No more than ____ disconnects per service can be grouped in one location.

A) two
B) four
C) six
D) eight
C
3
Derating is allowed for a total of four (or more) ____.

A) fastened-in-place appliances
B) branch circuits
C) kitchen receptacles
D) basement receptacles
A
4
All 15- or 20-ampere general-use receptacle outlets (except for small-appliance and laundry) are considered part of the ____.

A) main branch
B) central service
C) general lighting load
D) general service
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
5
The term appliance designates ____ equipment installed as a unit to perform specific function(s).

A) laundry
B) kitchen
C) compliance
D) utilization
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
6
In a multiple-occupancy building, each occupant must have access to the unit's ____.

A) main feeder line
B) service meter
C) fuse box
D) service disconnecting means
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
7
A load calculation on an individual unit in a multifamily dwelling must be calculated in accordance with one of the ____.

A) multi-family dwelling load-calculation methods
B) multi-family dwelling load-calculation methods and divided by the number of units per floor
C) one-family dwelling load-calculation methods
D) one-family dwelling load-calculation methods and multiplied by the number of units per floor
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
8
When calculating load, household cooking appliances rated over ____ kW should be included.

A) 1.25
B) 1.50
C) 1.75
D) 10
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
9
When calculating appliance load in a one-family dwelling, ____ should be used.

A) demand factors
B) compliance ratings
C) BTUs
D) nameplate ratings
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
10
The service disconnecting means for a standard load calculation for a single unit of a multifamily dwelling must have a rating of at least ____.

A) the calculated load
B) the load for a single unit
C) one quarter the total load
D) one half the total load
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
11
A heat pump with supplementary heat is ____.

A) considered a coincident load
B) not considered a noncoincident load
C) sometimes considered a coincident load
D) sometimes considered a noncoincident load
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
12
Each laundry branch circuit is calculated at no less than ____ volt-amperes.

A) 1000
B) 1100
C) 1200
D) 1500
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
13
A clothes dryer neutral load on a feeder is calculated at ____%.

A) 50
B) 60
C) 70
D) 80
Unlock Deck
Unlock for access to all 14 flashcards in this deck.
Unlock Deck
k this deck
14
Electric heating loads (including associated motors) are calculated at ____% of the total connected load.

A) 75
B) 100
C) 125
D) 150