Deck 36: The Short-Cycle Timer

Full screen (f)
exit full mode
Question
A ____ thermostat wire can cause a bad connection that will cause the compressor to alternately start and stop.

A) short
B) loose
C) long
D) tight
Use Space or
up arrow
down arrow
to flip the card.
Question
The delay-on-break short-cycle timer begins its timing sequence when the thermostat contacts close.
Question
Short cycling is a condition that occurs when the compressor is turned off immediately after the pressure has been stabilized.
Question
The short-cycling timer is controlled by the ____.

A) thermostat
B) relay
C) transformer
D) motor
Question
Short cycling can be acceptable in some cases.
Question
After a compressor has been turned off, enough time should be permitted to pass to allow the ____ before it is restarted.

A) pressure in the system to increase
B) charge in the evaporator to reverse
C) charge in the condenser to stabilize
D) pressure in the system to equalize
Question
Many short-cycle timers use electronic components to affect a time delay.
Question
Electronic short-cycle timers can be obtained that operate as delay-on-make or as ____.

A) delay-on-pass
B) on-delay
C) delay-on-break
D) delay-on-check
Question
Some electronic controls combine more than one function in a single unit.
Question
The short-cycling timer is a cam-operated, motor driven, ____.

A) on-delay timer
B) digital timer
C) delay-on-brake timer
D) programmed timer
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 36: The Short-Cycle Timer
1
A ____ thermostat wire can cause a bad connection that will cause the compressor to alternately start and stop.

A) short
B) loose
C) long
D) tight
loose
2
The delay-on-break short-cycle timer begins its timing sequence when the thermostat contacts close.
False
3
Short cycling is a condition that occurs when the compressor is turned off immediately after the pressure has been stabilized.
False
4
The short-cycling timer is controlled by the ____.

A) thermostat
B) relay
C) transformer
D) motor
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Short cycling can be acceptable in some cases.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
After a compressor has been turned off, enough time should be permitted to pass to allow the ____ before it is restarted.

A) pressure in the system to increase
B) charge in the evaporator to reverse
C) charge in the condenser to stabilize
D) pressure in the system to equalize
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
Many short-cycle timers use electronic components to affect a time delay.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Electronic short-cycle timers can be obtained that operate as delay-on-make or as ____.

A) delay-on-pass
B) on-delay
C) delay-on-break
D) delay-on-check
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Some electronic controls combine more than one function in a single unit.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
The short-cycling timer is a cam-operated, motor driven, ____.

A) on-delay timer
B) digital timer
C) delay-on-brake timer
D) programmed timer
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.