Deck 22: Overloads

Full screen (f)
exit full mode
Question
Overload units are designed to open their contacts when the motor current reaches ____ of full-load current.

A) 95% to 105%
B) 105% to 115%
C) 115% to 125%
D) 125% to 135%
Use Space or
up arrow
down arrow
to flip the card.
Question
Each phase of a three-phase motor should be protected by an overload relay.
Question
The bimetal type of overload operates very differently from the solder-melting type.
Question
The bimetal type of overload unit is used to a large extent on commercial and industrial air conditioning units.
Question
Since the overload unit must be sensitive to motor current, the heater of the overload relay is connected ____.

A) above the motor
B) in parallel with the motor
C) below the motor
D) in series with the motor
Question
The solder-melting type overload relay has two separate sections: the heater section and the contact section.
Question
Most overload relays are operated by ____.

A) pressure
B) pneumatic controls
C) heat
D) magnetism
Question
The solder-melting type of overload relay has a set of small ____ that are intended to interrupt the current flow in the control circuit only.

A) contactors
B) auxiliary contacts
C) programmable controllers
D) timers
Question
Overload relays will trip faster in hot weather than they will in cool weather.
Question
Single-phase motors are generally protected with a small ____ reset overload.

A) automatic
B) electronic
C) manual
D) battery-powered
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 22: Overloads
1
Overload units are designed to open their contacts when the motor current reaches ____ of full-load current.

A) 95% to 105%
B) 105% to 115%
C) 115% to 125%
D) 125% to 135%
115% to 125%
2
Each phase of a three-phase motor should be protected by an overload relay.
True
3
The bimetal type of overload operates very differently from the solder-melting type.
False
4
The bimetal type of overload unit is used to a large extent on commercial and industrial air conditioning units.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
Since the overload unit must be sensitive to motor current, the heater of the overload relay is connected ____.

A) above the motor
B) in parallel with the motor
C) below the motor
D) in series with the motor
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
The solder-melting type overload relay has two separate sections: the heater section and the contact section.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
Most overload relays are operated by ____.

A) pressure
B) pneumatic controls
C) heat
D) magnetism
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
The solder-melting type of overload relay has a set of small ____ that are intended to interrupt the current flow in the control circuit only.

A) contactors
B) auxiliary contacts
C) programmable controllers
D) timers
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
Overload relays will trip faster in hot weather than they will in cool weather.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
Single-phase motors are generally protected with a small ____ reset overload.

A) automatic
B) electronic
C) manual
D) battery-powered
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.