Deck 6: Equipment Grounding and Equipment Grounding Conductors

Full screen (f)
exit full mode
Question
If the combined length of flexible metal conduit and flexible metallic tubing and liquidtight flexible metal conduit in the same ground return path does not exceed ____, it is recognized as an equipment grounding conductor.

A) 2 feet
B) 4 feet
C) 6 feet
D) 8 feet
Use Space or
up arrow
down arrow
to flip the card.
Question
In residential occupancies, stationary and fixed motor-operated tools are not required to be connected to an equipment grounding conductor.
Question
Type MC cable is manufactured in three broad types: interlocked metal tape, smooth tube, and ____________________.
Question
Additional insulated grounding conductors have either a ____ stripe, surface marking, or both to indicate that they are additional equipment or isolated grounding conductors.

A) red
B) blue
C) yellow
D) black
Question
The termination temperature for a conductor is usually ____.

A) 50°C
B) 75°C
C) 100°C
D) 105°C
Question
What color is used for the identification of wiring device terminals?

A) red
B) blue
C) orange
D) green
Question
First-break, last-make of the equipment grounding conductor is not required where interlocked equipment, plugs, receptacles, and connectors prevent energization without grounding continuity.
Question
Exposed noncurrent-carrying metal parts are capable of carrying current if accidentally energized.
Question
For the 25-ft (7.5-m) tap rule, the ____________________ of the smaller conductors must be not less than one-third of the rating of the upstream overcurrent protective device.
Question
____ connectors are intended for use only with cable employing corrugated copper tube.

A) Bronze
B) Aluminum
C) Metal-clad
D) Steel
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 6: Equipment Grounding and Equipment Grounding Conductors
1
If the combined length of flexible metal conduit and flexible metallic tubing and liquidtight flexible metal conduit in the same ground return path does not exceed ____, it is recognized as an equipment grounding conductor.

A) 2 feet
B) 4 feet
C) 6 feet
D) 8 feet
C
2
In residential occupancies, stationary and fixed motor-operated tools are not required to be connected to an equipment grounding conductor.
False
3
Type MC cable is manufactured in three broad types: interlocked metal tape, smooth tube, and ____________________.
corrugated tube
4
Additional insulated grounding conductors have either a ____ stripe, surface marking, or both to indicate that they are additional equipment or isolated grounding conductors.

A) red
B) blue
C) yellow
D) black
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
5
The termination temperature for a conductor is usually ____.

A) 50°C
B) 75°C
C) 100°C
D) 105°C
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
6
What color is used for the identification of wiring device terminals?

A) red
B) blue
C) orange
D) green
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
7
First-break, last-make of the equipment grounding conductor is not required where interlocked equipment, plugs, receptacles, and connectors prevent energization without grounding continuity.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
8
Exposed noncurrent-carrying metal parts are capable of carrying current if accidentally energized.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
9
For the 25-ft (7.5-m) tap rule, the ____________________ of the smaller conductors must be not less than one-third of the rating of the upstream overcurrent protective device.
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
10
____ connectors are intended for use only with cable employing corrugated copper tube.

A) Bronze
B) Aluminum
C) Metal-clad
D) Steel
Unlock Deck
Unlock for access to all 10 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 10 flashcards in this deck.