1
Describe the schematic symbols for push buttons.
A very common schematic symbol is the push button. Normally open push buttons are shown with the movable contact above and not touching the two stationary contacts. The symbol indicates that when finger pressure is applied to the movable contact, it travels downward and bridges the gap between the two stationary contacts. Normally closed push button symbols are drawn with the movable contact below and touching the stationary contacts. When pressure is applied to the movable contact it travels downward and breaks the connection between the two stationary contacts. Another very common push button symbol is the double acting push button. Double acting push buttons contain both normally open and normally closed contacts with one movable contact.
2
The control circuit is often referred to as the basic circuit.
A) three-wire
B) forward-reverse
C) start-stop push-button
D) air-conditioning
A) three-wire
B) forward-reverse
C) start-stop push-button
D) air-conditioning
C
3
switches are indicated by drawing a wedge shape below the movable contact of a switch symbol.
A) Axial
B) Stationary
C) Normally open
D) Limit
A) Axial
B) Stationary
C) Normally open
D) Limit
D
4
What does the abbreviation NO stand for with reference to switch contacts?
A) normally obverse
B) natural ordering
C) normally open
D) never open
A) normally obverse
B) natural ordering
C) normally open
D) never open
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Bimetal strip-type overload relays generally permit the trip current to be adjusted to between 85% and % of the heater rating.
A) 95
B) 105
C) 115
D) 125
A) 95
B) 105
C) 115
D) 125
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
What are the major rules that should be followed when reading a schematic diagram?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
All overload relays contain two separate sections, the section and the control contact section.
A) voltage-sensing
B) voltage-modulating
C) current-sensing
D) resistance-modulating
A) voltage-sensing
B) voltage-modulating
C) current-sensing
D) resistance-modulating
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
A magnetic contactor or relay is basically an electrical that closes a set of contacts when the coil is energized.
A) bar magnet
B) pole
C) dipole magnet
D) solenoid
A) bar magnet
B) pole
C) dipole magnet
D) solenoid
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
If a contact is to be drawn it is drawn so that the movable contact is above and touching the stationary contact.
A) normally closed
B) normally open
C) normally open held closed
D) normally closed held open
A) normally closed
B) normally open
C) normally open held closed
D) normally closed held open
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
If the symbol shows the movable contact touching but below the stationary contact, this indicates that the switch is ____.
A) normally open held closed
B) normally closed held open
C) normally closed
D) normally open
A) normally open held closed
B) normally closed held open
C) normally closed
D) normally open
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
diagrams show components in their electrical sequence without regard for physical location.
A) Wiring
B) Schematic
C) Control
D) Contact
A) Wiring
B) Schematic
C) Control
D) Contact
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
A pressure switch is drawn by connecting a to a line.
A) rectangle
B) square
C) semicircle
D) triangle
A) rectangle
B) square
C) semicircle
D) triangle
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
What is the difference between overload protection and fuse or circuit protection?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
What are relays and contactors?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
There are two types of thermal overload relays, the type and the bimetal strip type.
A) transistor
B) solder pot
C) rheostat
D) serrated wheel
A) transistor
B) solder pot
C) rheostat
D) serrated wheel
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
The current-sensing section of the overload relay can be , electronic, or thermal.
A) pressure-based
B) integrated
C) solar
D) magnetic
A) pressure-based
B) integrated
C) solar
D) magnetic
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
are intended to open the circuit when the current exceeds the full-load current rating of the motor by 115 percent to 125 percent.
A) Fuses
B) Overloads
C) Circuit breakers
D) Trip wires
A) Fuses
B) Overloads
C) Circuit breakers
D) Trip wires
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
In a basic air-conditioning circuit there are two switches in order to protect the compressor from extremes.
A) pressure
B) temperature
C) flow
D) float
A) pressure
B) temperature
C) flow
D) float
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
What are the differences between the two types of thermal overload relays?
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Motor control circuits can be divided into two major categories, one of which is .
A) three-wire
B) limit switching
C) float switching
D) deceleration
A) three-wire
B) limit switching
C) float switching
D) deceleration
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck