Deck 28: Overcurrent Protectionfuses and Circuit Breakers
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Question
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
Play
Full screen (f)
Deck 28: Overcurrent Protectionfuses and Circuit Breakers
1
A(n) ____ is a condition where a hot conductor comes into contact with a grounded surface.
A) ground fault
B) short circuit
C) overload
D) open
A) ground fault
B) short circuit
C) overload
D) open
A
2
With a ____ fuse, one fuse element opens quickly when a short circuit, heavy overload, or ground fault occurs, and the other element in series with the first element opens slowly on overload conditions.
A) time-delay, dual-element
B) time-delay, loaded link
C) nontime-delay
D) nontime-delay, single element
A) time-delay, dual-element
B) time-delay, loaded link
C) nontime-delay
D) nontime-delay, single element
A
3
Plug fuses shall have a(n) ____ configuration somewhere on the fuse when rated at 15 amperes or less.
A) rectangular
B) octagonal
C) square
D) hexagonal
A) rectangular
B) octagonal
C) square
D) hexagonal
D
4
Circuit breakers with an interrupting rating other than ____ shall have this rating marked on the breaker.
A) 100 amperes
B) 5000 amperes
C) 10,000 amperes
D) none of the above
A) 100 amperes
B) 5000 amperes
C) 10,000 amperes
D) none of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
The maximum ampere rating of a Type S fuse is ____.
A) 15
B) 20
C) 30
D) 60
A) 15
B) 20
C) 30
D) 60
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
Cartridge fuses are available in Class H and Class R types.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Identified handle ties are permitted to disconnect all conductors of a service as long as it takes no more than ____________________ operations of the hand to shut everything off.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
Nontime-delay fuses are not the best choice for motor circuits because of the high starting inrush current of motors.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
____ fuses are special-purpose fuses that are found in original equipment, or in commercial and industrial panelboards, multimetering equipment, and motor controllers.
A) Class BB, Class A, and Class D
B) Class CC, Class G, and Class T
C) Class G, Class UU, and Class T
D) Class CH, Class I, and Class T
A) Class BB, Class A, and Class D
B) Class CC, Class G, and Class T
C) Class G, Class UU, and Class T
D) Class CH, Class I, and Class T
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
____________________ loading of a circuit is when the current flowing is within the capability of the circuit and/or the connected equipment.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
The term ____________________ refers to how long it will take a fuse or circuit breaker to open under different current values.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
A(n) ____ is a condition where the current flowing in a circuit is more than the current or equipment is designed to handle.
A) ground fault
B) short circuit
C) overload
D) open
A) ground fault
B) short circuit
C) overload
D) open
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
Current-limiting overcurrent devices will limit the amount of ____________________ by opening so fast that the full value of fault-current will not be reached
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
A(n) ____________________ is a condition where the current flowing in a circuit is more than the current or equipment is designed to handle.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
A(n) ____ is a condition where two or more conductors come into contact with one another.
A) ground fault
B) short circuit
C) overload
D) open
A) ground fault
B) short circuit
C) overload
D) open
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
All new plug fuse installations shall be ____________________ fuses.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
A(n) ____________________ is a condition where two or more conductors come into contact with one another.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
Fuses are not a reliable or economical form of overcurrent protection.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
A(n) ____________________ is a condition where a hot conductor comes into contact with a grounded surface.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
Overcurrent protection for residential services, branch circuits, and feeders is provided by circuit breakers or fuses. These are the "____" of an electrical circuit.
A) life forces
B) backup
C) safety valves
D) none of the above
A) life forces
B) backup
C) safety valves
D) none of the above
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck