Deck 7: Sensors and Transducers

Full screen (f)
exit full mode
Question
Which sensor is used in mobile phones?

A)Capacitive touch sensor
B)Temperature sensor
C)Humidity sensor
D)Weight sensor
Use Space or
up arrow
down arrow
to flip the card.
Question
The nano particles from iron and palladium are used to produce ________

A)Magnets
B)Magnetic lens
C)Magneto meters
D)Magnetic storage devices
Question
Nano particles target the rare _______ causing cells and remove them from blood.

A)Tumour
B)Fever
C)Infection
D)Cold
Question
___________ is the field in which the nano particles are used with silica coated iron oxide iron oxide.

A)Magnetic applications
B)Electronics
C)Medical diagnosis
D)Structural and mechanical materials
Question
In which of the following categories be thin plate diaphragm included?

A)Primary transducer
B)Secondary transducer
C)Voltage measuring devices
D)Spring balance systems
Question
Which of the following applications are suited for thin plate diaphragms?

A)Static pressure only
B)Dynamic pressure only
C)Both static and dynamic pressure with large frequency
D)Both static and dynamic pressure with small frequency
Question
Which of the following devices convert pressure to displacement?

A)Diaphragm
B)Bellow
C)Capsule
D)Both diaphragm and capsule
Question
Resistance temperature detector is ___________

A)a electrical tranducer
B)a mechanical transducer
C)a chemical transducer
D)a physical transducer
Question
Relation between temperature and resistance of a conductor is ________

A)Rt = Rref [1+t]
B)Rt = Rref [1+??t]
C)Rt = Rref [1-?t]
D)Rt = Rref [1-t]
Question
Sensing element in the thermometer must provide ________

A)small change in resistance
B)no change in resistance
C)large change in resistance
D)infinite change in resistance
Question
Resistive transducers are ______________

A)Primary transducers
B)Secondary transducers
C)Either primary or secondary
D)None of the mentioned
Question
Which of the following can be used to measure using thermistors?

A)Very low
B)In-between 100? and 1M?
C)Greater than 1M?
D)None of the mentioned
Question
Which of the following is correct for thermistors?

A)Positive temperature coefficient of resistance
B)Negative temperature coefficient of resistance
C)Unpredictable temperature coefficient
D)None of the mentioned
Question
Thermocouple is a ______________

A)Primary device
B)Secondary transducer
C)Tertiary transducer
D)None of the mentioned
Question
Operation of thermocouple is governed by _______________

A)Peltier effect
B)Seebeck effect
C)Thomson effect
D)All of the mentioned
Question
______________ describes current flow between two junctions formed by two different metals.

A)Peltier effect
B)Thomson effect
C)Seebeck effect
D)None of the mentioned
Question
Amount of heat liberated or absorbed when 1A current passes is called ____________

A)Thomson coefficient
B)Peltier coefficient
C)Seebeck coefficient
D)None of the mentioned
Question
Thermo couple cannot be used to measure ____________

A)Temperature of gas
B)Temperature of liquid
C)IR radiation
D)None of the mentioned
Question
Photoconductive transducers produce output ________

A)due to change in inductance
B)due to change in light
C)due to change in resistance
D)due to change in temperature
Question
Which of the following is correct for a level to force conversions?

A)Liquid at constant density distribution
B)Liquid with different density distribution
C)Level difference should be gradual
D)Liquid should be highly viscous
Question
Which devices measures gases or liquid?

A)Proximity sensor
B)Pressure sensor
C)Temperature sensor
D)Touch sensor
Question
Diaphragms in a pressure sensor are of ________

A)2 types
B)5 types
C)10 types
D)20 types
Question
Thermocouples consist of a pair of wires made of dissimilar metals joined together at one or more junctions that generate a voltage when subjected to a temperature gradient . This phenomenon is known as the _________

A)Seebeck effect
B)Piezolelectric effect
C)Photovoltaic
D)Photoconductor
Question
What is the name of the question mark area?

A)Measuring junction
B)Bridge junction
C)Temperature junction
D)Compensating junction
Question
Signal conditioner is used for _________

A)attenuating the voltage
B)maintaining a constant voltage
C)keeping the voltage zero
D)boosting the voltage
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 7: Sensors and Transducers
1
Which sensor is used in mobile phones?

A)Capacitive touch sensor
B)Temperature sensor
C)Humidity sensor
D)Weight sensor
Capacitive touch sensor
2
The nano particles from iron and palladium are used to produce ________

A)Magnets
B)Magnetic lens
C)Magneto meters
D)Magnetic storage devices
Magnetic storage devices
3
Nano particles target the rare _______ causing cells and remove them from blood.

A)Tumour
B)Fever
C)Infection
D)Cold
Tumour
4
___________ is the field in which the nano particles are used with silica coated iron oxide iron oxide.

A)Magnetic applications
B)Electronics
C)Medical diagnosis
D)Structural and mechanical materials
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
5
In which of the following categories be thin plate diaphragm included?

A)Primary transducer
B)Secondary transducer
C)Voltage measuring devices
D)Spring balance systems
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
6
Which of the following applications are suited for thin plate diaphragms?

A)Static pressure only
B)Dynamic pressure only
C)Both static and dynamic pressure with large frequency
D)Both static and dynamic pressure with small frequency
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
7
Which of the following devices convert pressure to displacement?

A)Diaphragm
B)Bellow
C)Capsule
D)Both diaphragm and capsule
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
8
Resistance temperature detector is ___________

A)a electrical tranducer
B)a mechanical transducer
C)a chemical transducer
D)a physical transducer
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
9
Relation between temperature and resistance of a conductor is ________

A)Rt = Rref [1+t]
B)Rt = Rref [1+??t]
C)Rt = Rref [1-?t]
D)Rt = Rref [1-t]
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
10
Sensing element in the thermometer must provide ________

A)small change in resistance
B)no change in resistance
C)large change in resistance
D)infinite change in resistance
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
11
Resistive transducers are ______________

A)Primary transducers
B)Secondary transducers
C)Either primary or secondary
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
12
Which of the following can be used to measure using thermistors?

A)Very low
B)In-between 100? and 1M?
C)Greater than 1M?
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following is correct for thermistors?

A)Positive temperature coefficient of resistance
B)Negative temperature coefficient of resistance
C)Unpredictable temperature coefficient
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
14
Thermocouple is a ______________

A)Primary device
B)Secondary transducer
C)Tertiary transducer
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
15
Operation of thermocouple is governed by _______________

A)Peltier effect
B)Seebeck effect
C)Thomson effect
D)All of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
16
______________ describes current flow between two junctions formed by two different metals.

A)Peltier effect
B)Thomson effect
C)Seebeck effect
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
17
Amount of heat liberated or absorbed when 1A current passes is called ____________

A)Thomson coefficient
B)Peltier coefficient
C)Seebeck coefficient
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
18
Thermo couple cannot be used to measure ____________

A)Temperature of gas
B)Temperature of liquid
C)IR radiation
D)None of the mentioned
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
19
Photoconductive transducers produce output ________

A)due to change in inductance
B)due to change in light
C)due to change in resistance
D)due to change in temperature
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
20
Which of the following is correct for a level to force conversions?

A)Liquid at constant density distribution
B)Liquid with different density distribution
C)Level difference should be gradual
D)Liquid should be highly viscous
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
21
Which devices measures gases or liquid?

A)Proximity sensor
B)Pressure sensor
C)Temperature sensor
D)Touch sensor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
22
Diaphragms in a pressure sensor are of ________

A)2 types
B)5 types
C)10 types
D)20 types
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
23
Thermocouples consist of a pair of wires made of dissimilar metals joined together at one or more junctions that generate a voltage when subjected to a temperature gradient . This phenomenon is known as the _________

A)Seebeck effect
B)Piezolelectric effect
C)Photovoltaic
D)Photoconductor
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
24
What is the name of the question mark area?

A)Measuring junction
B)Bridge junction
C)Temperature junction
D)Compensating junction
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
25
Signal conditioner is used for _________

A)attenuating the voltage
B)maintaining a constant voltage
C)keeping the voltage zero
D)boosting the voltage
Unlock Deck
Unlock for access to all 25 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 25 flashcards in this deck.