Deck 2: Measurement System and Transducer

Full screen (f)
exit full mode
Question
In a measuring system quantity under measurement is termed as ________________

A)Measurand
B)Controllers
C)Sensors
D)Indicators
Use Space or
up arrow
down arrow
to flip the card.
Question
_ _ _ _ _ is the complicated output signal types

A)Analog voltage
B)PWM
C)Serial digital
D)All the above
Question
Which of the following is not a characteristic of an ideal transducer?

A)High dynamic range
B)Low linearity
C)High repeatability
D)Low noise
Question
_ _ _ _ _ _ _ signals are much more susceptible to noise

A)Analog signal
B)Digital signal
C)Both Analog and Digital signal
D)None of the above
Question
_ _ _ _ _ _ is the closeness to true value

A)Zero stability
B)Accuracy
C)Sensitivity
D)Linearity
Question
The simplest model for a measurement system is a _ _ _ _ order differential equation

A)Zero
B)First
C)Second
D)Third
Question
Probable error is due to _ _ _ _ _ _.

A)Systematic error
B)Gross error
C)Random error
D)None of the mentioned
Question
_ _ _ _ _ is the value which occurs most frequently in a set of observations and around which other items of the set cluster densely

A)Mean
B)Median
C)Mode
D)Variance
Question
_ _ _ _ _ __ parameters on which sensor classified?

A)Material and technology
B)Application
C)Property and input quantity
D)All the above
Question
In a measuring system what is the term used to specify a difference between higher and lower calibration values?

A)Range
B)Span
C)Drift
D)Threshold
Question
Which of the following represent active transducer?

A)Strain gauge
B)Thermistor
C)LVDT
D)Thermocouple
Question
Capacitive transducer is used for?

A)Static measurement
B)Dynamic measurement
C)Transient measurement
D)Both static and dynamic
Question
The mercury in glass thermometer is an example of a _ _ _ _ _ _ order instrument

A)Zero
B)First
C)Second
D)Third
Question
_ _ __ _Senses the physical changes occur in the surrounding and converting it into a readable quantity.

A)Transducer
B)Actuator
C)Relay
D)Sensor
Question
A _ _ _ _ means that the sensor output is higher or lower than the ideal output.

A)Offset
B)Sensitivity
C)Linearity
D)Resolution
Question
The _ _ _ _ _characteristics of a transducer refer to the performance of the transducer when it is subjected to time varying signal.

A)Static
B)Dynamic
C)Transient
D)Both a and b
Question
A common example of a _ _ _ _ _ _ _ is to calibrate a temperature sensor using an ice-water bath and boiling water for the two references.

A)One point calibration
B)Two point calibration
C)Three point calibration
D)Both a and b
Question
___________, relating the sensor performance after or during exposure to specified external conditions (e.g. pressure, temperature, vibration and radiation).

A)Static characteristics
B)Dynamic characteristics
C)Environmental characteristics
D)Reliability Characteristics
Question
A _ _ _ _ __ much more immune to noise than an analog signal

A)Analog voltage
B)PWM
C)Serial digital
D)All the above
Question
Sensor and signal conditioning jointly referred as __ _ __

A)Transducer
B)Actuator
C)Relay
D)All the above
Question
The most common techniques for noise reduction are differential signal transmission and passive low pass _ _ _ _

A)Filtration
B)Amplifier
C)Relay
D)All the above
Question
Which of the following is caused by careless handling?

A)Systematic error
B)Gross error
C)Random error
D)None of the mentioned
Question
Bonding element in a strain gauge must have __________

A)zero insulation resistance
B)low insulation resistance
C)high insulation resistance
D)infinite insulation resistance
Question
In AMR the resistance produced by scattering is_ _ _ _ __ when the magnetization direction is parallel to the current direction

A)Zero
B)Minimum
C)Maximum
D)infinite
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/24
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 2: Measurement System and Transducer
1
In a measuring system quantity under measurement is termed as ________________

A)Measurand
B)Controllers
C)Sensors
D)Indicators
Measurand
2
_ _ _ _ _ is the complicated output signal types

A)Analog voltage
B)PWM
C)Serial digital
D)All the above
Serial digital
3
Which of the following is not a characteristic of an ideal transducer?

A)High dynamic range
B)Low linearity
C)High repeatability
D)Low noise
Low linearity
4
_ _ _ _ _ _ _ signals are much more susceptible to noise

A)Analog signal
B)Digital signal
C)Both Analog and Digital signal
D)None of the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
5
_ _ _ _ _ _ is the closeness to true value

A)Zero stability
B)Accuracy
C)Sensitivity
D)Linearity
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
6
The simplest model for a measurement system is a _ _ _ _ order differential equation

A)Zero
B)First
C)Second
D)Third
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
7
Probable error is due to _ _ _ _ _ _.

A)Systematic error
B)Gross error
C)Random error
D)None of the mentioned
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
8
_ _ _ _ _ is the value which occurs most frequently in a set of observations and around which other items of the set cluster densely

A)Mean
B)Median
C)Mode
D)Variance
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
9
_ _ _ _ _ __ parameters on which sensor classified?

A)Material and technology
B)Application
C)Property and input quantity
D)All the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
10
In a measuring system what is the term used to specify a difference between higher and lower calibration values?

A)Range
B)Span
C)Drift
D)Threshold
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
11
Which of the following represent active transducer?

A)Strain gauge
B)Thermistor
C)LVDT
D)Thermocouple
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
12
Capacitive transducer is used for?

A)Static measurement
B)Dynamic measurement
C)Transient measurement
D)Both static and dynamic
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
13
The mercury in glass thermometer is an example of a _ _ _ _ _ _ order instrument

A)Zero
B)First
C)Second
D)Third
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
14
_ _ __ _Senses the physical changes occur in the surrounding and converting it into a readable quantity.

A)Transducer
B)Actuator
C)Relay
D)Sensor
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
15
A _ _ _ _ means that the sensor output is higher or lower than the ideal output.

A)Offset
B)Sensitivity
C)Linearity
D)Resolution
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
16
The _ _ _ _ _characteristics of a transducer refer to the performance of the transducer when it is subjected to time varying signal.

A)Static
B)Dynamic
C)Transient
D)Both a and b
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
17
A common example of a _ _ _ _ _ _ _ is to calibrate a temperature sensor using an ice-water bath and boiling water for the two references.

A)One point calibration
B)Two point calibration
C)Three point calibration
D)Both a and b
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
18
___________, relating the sensor performance after or during exposure to specified external conditions (e.g. pressure, temperature, vibration and radiation).

A)Static characteristics
B)Dynamic characteristics
C)Environmental characteristics
D)Reliability Characteristics
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
19
A _ _ _ _ __ much more immune to noise than an analog signal

A)Analog voltage
B)PWM
C)Serial digital
D)All the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
20
Sensor and signal conditioning jointly referred as __ _ __

A)Transducer
B)Actuator
C)Relay
D)All the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
21
The most common techniques for noise reduction are differential signal transmission and passive low pass _ _ _ _

A)Filtration
B)Amplifier
C)Relay
D)All the above
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
22
Which of the following is caused by careless handling?

A)Systematic error
B)Gross error
C)Random error
D)None of the mentioned
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
23
Bonding element in a strain gauge must have __________

A)zero insulation resistance
B)low insulation resistance
C)high insulation resistance
D)infinite insulation resistance
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
24
In AMR the resistance produced by scattering is_ _ _ _ __ when the magnetization direction is parallel to the current direction

A)Zero
B)Minimum
C)Maximum
D)infinite
Unlock Deck
Unlock for access to all 24 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 24 flashcards in this deck.