Deck 24: Plumbing Codes: Nonpotable Water Systems

Full screen (f)
exit full mode
Question
Which of the following is NOT a source of gray water?

A)swimming pool backflush operations
B)air conditioning condensate
C)foundation drain water
D)kitchen sinks
Use Space or
up arrow
down arrow
to flip the card.
Question
As a rule, most codes require the overflow pipe from a nonpotable water tank to be of what size compared to the inlet piping?

A)half
B)equal to
C)double
D)three times as large
Question
When vents are used for storage thanks, the 2015 Uniform Plumbing code requires that the pipes serving as vents terminate a minimum of what distance above grade?

A)1 foot
B)3 inches
C)10 inches
D)6 inches
Question
Most codes demand that nonpotable water systems must have a minimum horizontal clearance of what distance from potable water wells?

A)10 feet
B)20 feet
C)100 feet
D)50 feet
Question
As a means to conserve our natural resources, many individuals and companies have turned to collecting black water for uses that do not require potable water.
Question
Who is required to keep an up-to-date maintenance log indicating the frequency of inspection and maintenance of nonpotable water systems?

A)local water board representative
B)code inspector
C)property owner
D)system installer
Question
Under what circumstances can nonpotable water be available for human consumption?

A)when there is a localized water shortage
B)when the user is interested in water conservation
C)when mixed with potable water
D)none of the above
Question
Most codes limit system pressure in nonpotable water systems employing pumps to what level of psi?

A)100 psi
B)60 psi
C)120 psi
D)80 psi
Question
At what point does the 2015 International Plumbing Code dictate that a nonpotable water system be designed by a registered design professional or person authorized by local jurisdiction?

A)discharge of more than 250 gallons per day
B)discharge of more than 360 gallons per day
C)discharge of more than 100 gallons per day
D)discharge of more than 150 gallons per day
Question
Most codes require nonpotable water piping to be what color as to visually distinguish it from potable water lines?

A)red
B)purple
C)black
D)orange
Question
How are gray water and reclaimed water different?

A)gray water is treated water
B)reclaimed water is safe for human consumption
C)reclaimed water is treated water
D)gray water is safe for animal consumption
Question
When the necessary system pressure cannot be achieved by elevating a tank, a pump is usually added.
Question
If a cross connection is found between a nonpotable and potable water system, what must be done before the potable water system can be put into permanent service?

A)it must be disinfected
B)it must be rebuilt, with new piping in affected areas
C)it must be flushed thoroughly
D)the nonpotable water system must be uninstalled
Question
Which of the following would NOT produce what the UPC defines as gray water?

A)laundry tubs
B)toilet
C)showers
D)clothes washers
Question
When a nonpotable water supply and a potable water system are located within the same property, the authority having jurisdiction may require a cross-connection test to prove that the building fixtures and systems are not crossed.
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 24: Plumbing Codes: Nonpotable Water Systems
1
Which of the following is NOT a source of gray water?

A)swimming pool backflush operations
B)air conditioning condensate
C)foundation drain water
D)kitchen sinks
D
2
As a rule, most codes require the overflow pipe from a nonpotable water tank to be of what size compared to the inlet piping?

A)half
B)equal to
C)double
D)three times as large
B
3
When vents are used for storage thanks, the 2015 Uniform Plumbing code requires that the pipes serving as vents terminate a minimum of what distance above grade?

A)1 foot
B)3 inches
C)10 inches
D)6 inches
D
4
Most codes demand that nonpotable water systems must have a minimum horizontal clearance of what distance from potable water wells?

A)10 feet
B)20 feet
C)100 feet
D)50 feet
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
As a means to conserve our natural resources, many individuals and companies have turned to collecting black water for uses that do not require potable water.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
Who is required to keep an up-to-date maintenance log indicating the frequency of inspection and maintenance of nonpotable water systems?

A)local water board representative
B)code inspector
C)property owner
D)system installer
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
Under what circumstances can nonpotable water be available for human consumption?

A)when there is a localized water shortage
B)when the user is interested in water conservation
C)when mixed with potable water
D)none of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Most codes limit system pressure in nonpotable water systems employing pumps to what level of psi?

A)100 psi
B)60 psi
C)120 psi
D)80 psi
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
At what point does the 2015 International Plumbing Code dictate that a nonpotable water system be designed by a registered design professional or person authorized by local jurisdiction?

A)discharge of more than 250 gallons per day
B)discharge of more than 360 gallons per day
C)discharge of more than 100 gallons per day
D)discharge of more than 150 gallons per day
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Most codes require nonpotable water piping to be what color as to visually distinguish it from potable water lines?

A)red
B)purple
C)black
D)orange
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
How are gray water and reclaimed water different?

A)gray water is treated water
B)reclaimed water is safe for human consumption
C)reclaimed water is treated water
D)gray water is safe for animal consumption
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
When the necessary system pressure cannot be achieved by elevating a tank, a pump is usually added.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
If a cross connection is found between a nonpotable and potable water system, what must be done before the potable water system can be put into permanent service?

A)it must be disinfected
B)it must be rebuilt, with new piping in affected areas
C)it must be flushed thoroughly
D)the nonpotable water system must be uninstalled
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
Which of the following would NOT produce what the UPC defines as gray water?

A)laundry tubs
B)toilet
C)showers
D)clothes washers
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
When a nonpotable water supply and a potable water system are located within the same property, the authority having jurisdiction may require a cross-connection test to prove that the building fixtures and systems are not crossed.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.