Deck 21: Plumbing Codes: Storm Drainage

Full screen (f)
exit full mode
Question
When performing a test on storm drainage systems, what is the minimum amount of time that the test should be held for?

A)10 minutes
B)5 minutes
C)20 minutes
D)15 minutes
Use Space or
up arrow
down arrow
to flip the card.
Question
The system of directing rainwater into a sanitary drainage system is known as:

A)a sanitary mix drainage system
B)a super dedicated drainage system
C)a combination drainage system
D)a redirection drainage system
Question
How much static head of pressure should each section have when planning a storm drainage system test?

A)at least 10
B)at least 5
C)at least 8
D)at least 15
Question
According to the UPC, when calculating the roof area for redirecting water, how much should be added for one wall?

A)100 percent of the wall area
B)50 percent of the wall area
C)75 percent of the wall area
D)125 percent of the wall area
Question
When a subsurface area is larger than 100 square feet, how is the drainpipe size determined?

A)by doubling up for every 100 square feet
B)similar to calculations for roof drains
C)multiplying the square footage by 2
D)adding 2 inches of pipe for every 50 square feet
Question
If a subsurface area has an area less than 100 square feet, what size pipe is suitable for directing water to a subsoil drain?

A)2-inch
B)1-inch
C)1 1/2-inch
D)1 1/4-inch
Question
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two opposite walls of differing heights?

A)35 percent of the wall area above the top of the lower wall
B)50 percent of the wall area above the top of the lower wall
C)75 percent of the wall area above the top of the lower wall
D)100 percent of the wall area above the top of the lower wall
Question
According to the IPC, when calculating the roof area for redirecting water, how much should be added?

A)one-half of the total area of the vertical surface
B)one-quarter of the total area of the vertical surface
C)one-third of the total area of the vertical surface
D)double the total area of the vertical surface
Question
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two adjacent walls of unequal heights?

A)35 percent of the wall area
B)50 percent of the wall area
C)75 percent of the wall area
D)100 percent of the wall area
Question
Today, only about half of large American cities have dedicated storm drainage systems.
Question
As cities began to grow, one of the first solutions for directing large amounts of rainwater out of cities was to direct rainwater into sanitary drainage systems.
Question
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two opposite walls of the same height?

A)no additional area
B)50 percent of the wall area
C)75 percent of the wall area
D)100 percent of the wall area
Question
Which of the following require either a floor drain, or sump pit to collect rainwater and divert it away from a building?

A)rooftop
B)vertical walls
C)signage
D)subsurface stairwell
Question
It is now illegal to direct rain runoff into sanitary drainage systems.
Question
Which type of area requires a means of collecting rainwater and redirecting it to areas where it will not cause a hazard?

A)parking lots
B)courtyards
C)buildings
D)all of the above
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 21: Plumbing Codes: Storm Drainage
1
When performing a test on storm drainage systems, what is the minimum amount of time that the test should be held for?

A)10 minutes
B)5 minutes
C)20 minutes
D)15 minutes
D
2
The system of directing rainwater into a sanitary drainage system is known as:

A)a sanitary mix drainage system
B)a super dedicated drainage system
C)a combination drainage system
D)a redirection drainage system
C
3
How much static head of pressure should each section have when planning a storm drainage system test?

A)at least 10
B)at least 5
C)at least 8
D)at least 15
A
4
According to the UPC, when calculating the roof area for redirecting water, how much should be added for one wall?

A)100 percent of the wall area
B)50 percent of the wall area
C)75 percent of the wall area
D)125 percent of the wall area
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
When a subsurface area is larger than 100 square feet, how is the drainpipe size determined?

A)by doubling up for every 100 square feet
B)similar to calculations for roof drains
C)multiplying the square footage by 2
D)adding 2 inches of pipe for every 50 square feet
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
If a subsurface area has an area less than 100 square feet, what size pipe is suitable for directing water to a subsoil drain?

A)2-inch
B)1-inch
C)1 1/2-inch
D)1 1/4-inch
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two opposite walls of differing heights?

A)35 percent of the wall area above the top of the lower wall
B)50 percent of the wall area above the top of the lower wall
C)75 percent of the wall area above the top of the lower wall
D)100 percent of the wall area above the top of the lower wall
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
According to the IPC, when calculating the roof area for redirecting water, how much should be added?

A)one-half of the total area of the vertical surface
B)one-quarter of the total area of the vertical surface
C)one-third of the total area of the vertical surface
D)double the total area of the vertical surface
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two adjacent walls of unequal heights?

A)35 percent of the wall area
B)50 percent of the wall area
C)75 percent of the wall area
D)100 percent of the wall area
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Today, only about half of large American cities have dedicated storm drainage systems.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
As cities began to grow, one of the first solutions for directing large amounts of rainwater out of cities was to direct rainwater into sanitary drainage systems.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
According to the UPC, when calculating the roof area for redirecting water, how much should be added for two opposite walls of the same height?

A)no additional area
B)50 percent of the wall area
C)75 percent of the wall area
D)100 percent of the wall area
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
Which of the following require either a floor drain, or sump pit to collect rainwater and divert it away from a building?

A)rooftop
B)vertical walls
C)signage
D)subsurface stairwell
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
It is now illegal to direct rain runoff into sanitary drainage systems.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
Which type of area requires a means of collecting rainwater and redirecting it to areas where it will not cause a hazard?

A)parking lots
B)courtyards
C)buildings
D)all of the above
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.