Deck 8: Heat Emitters

Full screen (f)
exit full mode
Question
Operating panel radiators at ____ water temperatures increases the percentage of radiant versus convective heat output from the panel.

A) lower
B) higher
C) thermally equalized
D) ambient
Use Space or
up arrow
down arrow
to flip the card.
Question
The heat output of finned-tube baseboard is expressed in Btu/hr./ft.of active element length.The active length of the element is the length of pipe ____.

A) under a source of downward drafts
B) nearest the riser's centerline
C) covered with fins
D) in the entire assembly
Question
To prevent corrosion, steel panel radiators should only be used in ____ systems.

A) open-loop
B) closed-loop
C) parallel
D) hydraulically calibrated
Question
Increasing the fluid flow rate through the coil will ____ increase the heating capacity of the fan-coil.

A) greatly
B) never
C) unpredictably
D) marginally
Question
Finned-tube baseboard convectors operate on the principle that heated air rises due to its lower density.
Question
The balance between convective heat transfer and radiative heat transfer can significantly affect the comfort achieved by various heat emitters.
Question
Hydronic fan-coils have two common components-a(n) ____ heat exchanger (often called the "coil") through which system fluid flows and a blower or fan that forces air to flow across the coil.

A) ceramic
B) cast iron
C) open-looped
D) finned-tube
Question
The heat output of a fan-coil is approximately proportional to the temperature difference between the entering air and entering water.
Question
A rule of thumb is to allow twice the linear footage of radiant baseboard compared to typical residential finned-tube baseboard.
Question
The head loss of radiant baseboard can be determined by considering each baseboard to be a tubing circuit approximately ____ as long as the baseboard extrusion.

A) twice
B) half
C) equally
D) three times
Question
Reverse return piping encourages equal flow rates and equal supply temperature to each radiator.
Question
The rate of heat transfer depends on either the temperature difference or the flow rate.
Question
A typical finned-tube baseboard convector.consists of a sheet metal enclosure containing a ____ tube fitted with aluminum fins.

A) copper
B) PEX
C) cast iron
D) stainless steel
Question
When baseboards are connected ____, each receives water at the temperature supplied to the manifold.

A) in series
B) in parallel
C) with copper tubing
D) to a thermostat
Question
As a rule, convectors are well suited for rooms with high ceilings.
Question
Parallel piping methods allow independent flow rate adjustment for each baseboard.
Question
Every hydronic heating system attempts to establish operating conditions that allow the distribution system to current rate of heat output from the heat source.This state is known as ____.

A) hydraulic channeling
B) thermal equilibrium
C) reverse return flow
D) radiant heat output
Question
When rooms lack the wall space needed to mount finned-tube baseboard, one alternative is to use a hydronic fan-coil.
Question
Panel radiators typically require much more wall space than fin-tube baseboard sized for equivalent heat output and operating conditions.
Question
One way that heat loss of bare copper tube can be evaluated is when the length of the copper tube in feet divided by the flow rate in gallons per minute exceeds ____ ft./gpm, there will be a greater temperature drop along the tube from inlet to outlet.

A) 5
B) 10
C) 15
D) 20
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 8: Heat Emitters
1
Operating panel radiators at ____ water temperatures increases the percentage of radiant versus convective heat output from the panel.

A) lower
B) higher
C) thermally equalized
D) ambient
A
2
The heat output of finned-tube baseboard is expressed in Btu/hr./ft.of active element length.The active length of the element is the length of pipe ____.

A) under a source of downward drafts
B) nearest the riser's centerline
C) covered with fins
D) in the entire assembly
C
3
To prevent corrosion, steel panel radiators should only be used in ____ systems.

A) open-loop
B) closed-loop
C) parallel
D) hydraulically calibrated
B
4
Increasing the fluid flow rate through the coil will ____ increase the heating capacity of the fan-coil.

A) greatly
B) never
C) unpredictably
D) marginally
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
5
Finned-tube baseboard convectors operate on the principle that heated air rises due to its lower density.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
6
The balance between convective heat transfer and radiative heat transfer can significantly affect the comfort achieved by various heat emitters.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
7
Hydronic fan-coils have two common components-a(n) ____ heat exchanger (often called the "coil") through which system fluid flows and a blower or fan that forces air to flow across the coil.

A) ceramic
B) cast iron
C) open-looped
D) finned-tube
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
8
The heat output of a fan-coil is approximately proportional to the temperature difference between the entering air and entering water.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
9
A rule of thumb is to allow twice the linear footage of radiant baseboard compared to typical residential finned-tube baseboard.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
10
The head loss of radiant baseboard can be determined by considering each baseboard to be a tubing circuit approximately ____ as long as the baseboard extrusion.

A) twice
B) half
C) equally
D) three times
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
11
Reverse return piping encourages equal flow rates and equal supply temperature to each radiator.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
12
The rate of heat transfer depends on either the temperature difference or the flow rate.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
13
A typical finned-tube baseboard convector.consists of a sheet metal enclosure containing a ____ tube fitted with aluminum fins.

A) copper
B) PEX
C) cast iron
D) stainless steel
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
14
When baseboards are connected ____, each receives water at the temperature supplied to the manifold.

A) in series
B) in parallel
C) with copper tubing
D) to a thermostat
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
15
As a rule, convectors are well suited for rooms with high ceilings.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
16
Parallel piping methods allow independent flow rate adjustment for each baseboard.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
17
Every hydronic heating system attempts to establish operating conditions that allow the distribution system to current rate of heat output from the heat source.This state is known as ____.

A) hydraulic channeling
B) thermal equilibrium
C) reverse return flow
D) radiant heat output
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
18
When rooms lack the wall space needed to mount finned-tube baseboard, one alternative is to use a hydronic fan-coil.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
19
Panel radiators typically require much more wall space than fin-tube baseboard sized for equivalent heat output and operating conditions.
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
20
One way that heat loss of bare copper tube can be evaluated is when the length of the copper tube in feet divided by the flow rate in gallons per minute exceeds ____ ft./gpm, there will be a greater temperature drop along the tube from inlet to outlet.

A) 5
B) 10
C) 15
D) 20
Unlock Deck
Unlock for access to all 20 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 20 flashcards in this deck.