Deck 27: Part Winding Starters

Full screen (f)
exit full mode
Question
In part winding starting, neither of the two windings is individually capable of withstanding the starting current for more than a few seconds.
Use Space or
up arrow
down arrow
to flip the card.
Question
Delta connected dual voltage motors are acceptable for part winding starting.
Question
Part winding starters provide closed transition starting.
Question
Motors designed to be used for part winding starting contain two separate stator windings. What are they?
Question
Part winding starting is typically used for motors that supply the moving force for centrifugal pumps, fans, and blowers.
Question
The method of starting in which only half the motor winding is used during starting is called ____________________ starting.
Question
With part winding starting, the first winding will ____________________ rapidly if the second windings is not connected within a very short period of time.
Question
Figure 27-2 Figure 27-2   In the accompanying figure, why are both overload relays connected in series?<div style=padding-top: 35px>
In the accompanying figure, why are both overload relays connected in series?
Question
When dual voltage motors are used, the motor must be operated on the high voltage setting of the motor.
Question
Each winding in motors designed for part winding starting is individually protected by ____________________ overload heaters.
Question
What happens if the second winding is not connected to the power line within a short period of time?
Question
The thermal capacity of the stator windings greatly limits the length of starting time for a part winding motor. How can you help overcome this problem?
Question
One advantage of part winding starters is that they provide ____________________ starting because the motor is never disconnected from the power line during the starting time.
Question
To help prevent damaging the first winding, some circuits contain a timer that disconnects power to the motor if the second winding is not energized within a predetermined time. This timer is often called a(n) ____________________.
Question
The thermal capacity of the stator windings greatly limits the length of starting time for a part winding motor. How do you overcome this problem?
Unlock Deck
Sign up to unlock the cards in this deck!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
Play
simple tutorial
Full screen (f)
exit full mode
Deck 27: Part Winding Starters
1
In part winding starting, neither of the two windings is individually capable of withstanding the starting current for more than a few seconds.
True
2
Delta connected dual voltage motors are acceptable for part winding starting.
False
3
Part winding starters provide closed transition starting.
True
4
Motors designed to be used for part winding starting contain two separate stator windings. What are they?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
5
Part winding starting is typically used for motors that supply the moving force for centrifugal pumps, fans, and blowers.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
6
The method of starting in which only half the motor winding is used during starting is called ____________________ starting.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
7
With part winding starting, the first winding will ____________________ rapidly if the second windings is not connected within a very short period of time.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
8
Figure 27-2 Figure 27-2   In the accompanying figure, why are both overload relays connected in series?
In the accompanying figure, why are both overload relays connected in series?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
9
When dual voltage motors are used, the motor must be operated on the high voltage setting of the motor.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
10
Each winding in motors designed for part winding starting is individually protected by ____________________ overload heaters.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
11
What happens if the second winding is not connected to the power line within a short period of time?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
12
The thermal capacity of the stator windings greatly limits the length of starting time for a part winding motor. How can you help overcome this problem?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
13
One advantage of part winding starters is that they provide ____________________ starting because the motor is never disconnected from the power line during the starting time.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
14
To help prevent damaging the first winding, some circuits contain a timer that disconnects power to the motor if the second winding is not energized within a predetermined time. This timer is often called a(n) ____________________.
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
15
The thermal capacity of the stator windings greatly limits the length of starting time for a part winding motor. How do you overcome this problem?
Unlock Deck
Unlock for access to all 15 flashcards in this deck.
Unlock Deck
k this deck
locked card icon
Unlock Deck
Unlock for access to all 15 flashcards in this deck.