Deck 5: Refrigerant System Componentsservicing System Components

ملء الشاشة (f)
exit full mode
سؤال
The EPA requires the replacement of hoses or seals during the retrofit of a vehicle from R-12 to R-134a.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The correct oil for use with R-134a is mineral oil.
سؤال
If a system has a thermostatic expansion valve,it will also have all of the following parts,EXCEPT:

A) accumulator.
B) compressor.
C) condenser.
D) receiver-drier.
سؤال
The expansion valve regulates the evaporator temperature based on the thermal heat load it detects.
سؤال
Technician A says that the thermostatic expansion valve may be located anywhere between the evaporator outlet and the compressor inlet.Technician B says that fixed orifice tubes sizes are interchangeable in order to taylor system performance.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Technician A says the amount of refrigerant flowing through an orifice tube is controlled by a remote sensing bulb.Technician B says the orifice tube is located in the liquid line between the condenser outlet and evaporator inlet.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Technician A says a receiver-drier is used in systems with a fixed orifice tube.Technician B says the receiver-drier stores reserve refrigerant.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
An H valve is often referred to as a block valve.
سؤال
Most vendors will not honor the warranty on a new or rebuilt compressor unless the ____ is replaced at the time of service.

A) accumulator
B) receiver-drier
C) expansion valve
D) a or b
سؤال
Tubing with a nylon lining can be used with both R-12 (CFC-12)and R-134a (HFC-134a)refrigerants.
سؤال
Most early R-12 hoses were not barrier hoses.
سؤال
The term purge an air-conditioning system in general terms means to:

A) Add sealant to the refrigerant system
B) Recharge the refrigerant system
C) Flush the refrigerant system.
D) Remove the refrigerant from the system.
سؤال
Before attempting to service an automotive air-conditioning system consider all of the following Except:

A) Can customer afford the repair?
B) Do you have the proper tools and equipment to service the system?
C) Listen to customer complaint.
D) Does your diagnosis make sense based on customer complaint.
سؤال
Removing spring lock fittings on refrigerant lines requires a special tool.
سؤال
Before installation: Technician A says that refrigerant system O-rings should be coated with new refrigerant oil.Technician B says refrigerant system O-rings can be coated with a gasket sealant.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
All of the following are reasons why a flooded evaporator will not cool well,EXCEPT:

A) High pressure in the evaporator prevents refrigerant vaporization.
B) There is no room for expansion.
C) The refrigerant vaporizes too quickly.
D) The refrigerant cannot take on heat.
سؤال
O-rings will not usually leak if they are reused.
سؤال
The compressor separates the low side from the high side of the system.
سؤال
Refrigerant enters the compressor as a

A) high-pressure vapor.
B) low-pressure vapor.
C) low-pressure liquid.
D) high-pressure liquid.
سؤال
If the evaporator is starved,superheat is very high.
سؤال
What type of desiccants are acceptable for use on R-134a systems?
سؤال
What effect will bent cooling fins on the condenser have on the refrigerant system?
سؤال
Why is the remote bulb of a thermostatic expansion valve attached with insulated tape to the refrigerant line?
سؤال
Define desiccant.
سؤال
What is meant by the term starved evaporator?
سؤال
The refrigerant from a vehicles A/C system is being recovered into a recovery unit.Technician A says that both the vapor and liquid tank valves on the recovery unit should be OPEN.Technician B says that both the high-side and low-side gauge valves on the manifold and gauge set should be OPEN.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Desiccant is being discussed.Technician A says both manufacturer-approved refrigerants use the same desiccant.Technician B says the desiccant in an accumulator can be replaced without replacing the accumulator.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Technician A says in an H-block valve the temperature sensing sleeve (bulb)is internally located in the outlet port of the valve.Technician B says the operation and function of the H-valve,or block valve,are essentially the same as the thermostatic expansion valve (TXV).Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Once the refrigerant from the air conditioning system has been recovered,which of the following should the technician do?

A) Check the purity of the refrigerant in the recovery tank.
B) Change the recovery unit fiters.
C) Record the amount of refrigerant oil removed from the system.
D) Change the receiver-drier.
سؤال
Define heat load.
سؤال
A flooded evaporator can cause damage to the

A) compressor.
B) condenser.
C) expansion valve.
D) receiver-drier.
سؤال
On an expansion valve system the valve opens and closes in relation to ______ temperature and pressure.

A) compressor
B) evaporator
C) accumuator
D) any of the above, depending on the manufacturer
سؤال
What is the purpose of the evaporator?
سؤال
Describe what happens to the refrigerant within the evaporator.
سؤال
Technician A says there are several condenser designs and flow paths in use today.Technician B says the only flow paths for refrigerant through the condenser's tubing is the parallel cross flow.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
A leaking evaporator is being replaced.Technician A says the new o-rings should be coated with clean refrigerant oil.Technician B says the some refrigerant oil shoud be added to the system prior to recharging the system.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
سؤال
Refrigerant leaves the evaporator as a

A) high-pressure vapor.
B) low-pressure vapor.
C) low-pressure liquid.
D) high-pressure liquid.
سؤال
If the refrigerant system is suspected of being contaminated with moisture what component should also be replaced?
سؤال
Why must the condenser outlet be at the bottom?
سؤال
Describe the two major functions of the air conditioning system compressor.
سؤال
What is the function of the evaporator case drain vent?
سؤال
What is a barrier hose and when must one be used?
سؤال
What is the function of the orifice tube?
سؤال
What is a flooded evaporator and how does it occur? What are the results of this condition?
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/44
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 5: Refrigerant System Componentsservicing System Components
1
The EPA requires the replacement of hoses or seals during the retrofit of a vehicle from R-12 to R-134a.
False
2
The correct oil for use with R-134a is mineral oil.
False
3
If a system has a thermostatic expansion valve,it will also have all of the following parts,EXCEPT:

A) accumulator.
B) compressor.
C) condenser.
D) receiver-drier.
A
4
The expansion valve regulates the evaporator temperature based on the thermal heat load it detects.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
5
Technician A says that the thermostatic expansion valve may be located anywhere between the evaporator outlet and the compressor inlet.Technician B says that fixed orifice tubes sizes are interchangeable in order to taylor system performance.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
6
Technician A says the amount of refrigerant flowing through an orifice tube is controlled by a remote sensing bulb.Technician B says the orifice tube is located in the liquid line between the condenser outlet and evaporator inlet.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
7
Technician A says a receiver-drier is used in systems with a fixed orifice tube.Technician B says the receiver-drier stores reserve refrigerant.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
8
An H valve is often referred to as a block valve.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
9
Most vendors will not honor the warranty on a new or rebuilt compressor unless the ____ is replaced at the time of service.

A) accumulator
B) receiver-drier
C) expansion valve
D) a or b
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
10
Tubing with a nylon lining can be used with both R-12 (CFC-12)and R-134a (HFC-134a)refrigerants.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
11
Most early R-12 hoses were not barrier hoses.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
12
The term purge an air-conditioning system in general terms means to:

A) Add sealant to the refrigerant system
B) Recharge the refrigerant system
C) Flush the refrigerant system.
D) Remove the refrigerant from the system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
13
Before attempting to service an automotive air-conditioning system consider all of the following Except:

A) Can customer afford the repair?
B) Do you have the proper tools and equipment to service the system?
C) Listen to customer complaint.
D) Does your diagnosis make sense based on customer complaint.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
14
Removing spring lock fittings on refrigerant lines requires a special tool.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
15
Before installation: Technician A says that refrigerant system O-rings should be coated with new refrigerant oil.Technician B says refrigerant system O-rings can be coated with a gasket sealant.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
16
All of the following are reasons why a flooded evaporator will not cool well,EXCEPT:

A) High pressure in the evaporator prevents refrigerant vaporization.
B) There is no room for expansion.
C) The refrigerant vaporizes too quickly.
D) The refrigerant cannot take on heat.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
17
O-rings will not usually leak if they are reused.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
18
The compressor separates the low side from the high side of the system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
19
Refrigerant enters the compressor as a

A) high-pressure vapor.
B) low-pressure vapor.
C) low-pressure liquid.
D) high-pressure liquid.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
20
If the evaporator is starved,superheat is very high.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
21
What type of desiccants are acceptable for use on R-134a systems?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
22
What effect will bent cooling fins on the condenser have on the refrigerant system?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
23
Why is the remote bulb of a thermostatic expansion valve attached with insulated tape to the refrigerant line?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
24
Define desiccant.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
25
What is meant by the term starved evaporator?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
26
The refrigerant from a vehicles A/C system is being recovered into a recovery unit.Technician A says that both the vapor and liquid tank valves on the recovery unit should be OPEN.Technician B says that both the high-side and low-side gauge valves on the manifold and gauge set should be OPEN.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
27
Desiccant is being discussed.Technician A says both manufacturer-approved refrigerants use the same desiccant.Technician B says the desiccant in an accumulator can be replaced without replacing the accumulator.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
28
Technician A says in an H-block valve the temperature sensing sleeve (bulb)is internally located in the outlet port of the valve.Technician B says the operation and function of the H-valve,or block valve,are essentially the same as the thermostatic expansion valve (TXV).Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
29
Once the refrigerant from the air conditioning system has been recovered,which of the following should the technician do?

A) Check the purity of the refrigerant in the recovery tank.
B) Change the recovery unit fiters.
C) Record the amount of refrigerant oil removed from the system.
D) Change the receiver-drier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
30
Define heat load.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
31
A flooded evaporator can cause damage to the

A) compressor.
B) condenser.
C) expansion valve.
D) receiver-drier.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
32
On an expansion valve system the valve opens and closes in relation to ______ temperature and pressure.

A) compressor
B) evaporator
C) accumuator
D) any of the above, depending on the manufacturer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
33
What is the purpose of the evaporator?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
34
Describe what happens to the refrigerant within the evaporator.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
35
Technician A says there are several condenser designs and flow paths in use today.Technician B says the only flow paths for refrigerant through the condenser's tubing is the parallel cross flow.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
36
A leaking evaporator is being replaced.Technician A says the new o-rings should be coated with clean refrigerant oil.Technician B says the some refrigerant oil shoud be added to the system prior to recharging the system.Who is correct?

A) Technician A only
B) Technician B only
C) Both A and B
D) Neither A nor B
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
37
Refrigerant leaves the evaporator as a

A) high-pressure vapor.
B) low-pressure vapor.
C) low-pressure liquid.
D) high-pressure liquid.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
38
If the refrigerant system is suspected of being contaminated with moisture what component should also be replaced?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
39
Why must the condenser outlet be at the bottom?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
40
Describe the two major functions of the air conditioning system compressor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
41
What is the function of the evaporator case drain vent?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
42
What is a barrier hose and when must one be used?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
43
What is the function of the orifice tube?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
44
What is a flooded evaporator and how does it occur? What are the results of this condition?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.