Deck 19: Bite-Wing Technique

ملء الشاشة (f)
exit full mode
سؤال
When taking a molar bite-wing image,in order to follow rule number 5 of the bite-wing technique,receptor exposure,what must the mesial part of the PID cover?

A)Mesial of the mandibular first molar
B)Both first molars
C)Mesial of the mandibular second premolar
D)Both second premolars
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
_______ sizes of bite-wing receptors are available.

A)Two
B)Three
C)Four
D)Six
سؤال
(1)Overlapped interproximal contacts are caused by improper vertical angulation.(2)To prevent overlap,the vertical angulation should be adjusted to +10 degrees.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
سؤال
Vertical bite-wings are often used for patients with

A)mixed dentition.
B)extensive decay.
C)bone loss.
D)sealants.
سؤال
When taking a premolar bite-wing image,in order to follow rule number 5 of the bite-wing technique,receptor exposure,what must the mesial part of the PID cover?

A)Both premolars
B)Both canines
C)Mandibular canine
D)Mandibular premolar
سؤال
In the adult patient,which size receptor is recommended for bite-wing exposures?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
سؤال
The problem with a single bite-wing receptor per side for adult patients is increased

A)x-ray exposure.
B)possibility of inciting the gag reflex.
C)overlapped contacts.
D)useful diagnostic information.
سؤال
What vertical angulation should you use when adjusting the PID to take bite-wing images with bite-tabs?

A)-10 degrees
B)0 degrees
C)+5 degrees
D)+10 degrees
سؤال
What modification in technique is recommended when the patient has an edentulous space causing a problem with bite-wing receptor placement?

A)Skip the bite-wing receptor.
B)Place a cotton roll in the area of the missing tooth or teeth.
C)Have the patient hold the receptor in position with a hemostat.
D)Take a periapical receptor with a bite-block instead.
سؤال
Your 35-year-old patient has clinical attachment loss in the posterior teeth.What type of bite-wing images should you take,and what size receptor should you use?

A)Horizontal;1
B)Horizontal;2
C)Vertical;1
D)Vertical;2
سؤال
(1)Size 3 receptor can only be used for bite-wing images.(2)Size 3 receptor is the recommended size for adult bite-wing images.

A)Both statements are true
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
سؤال
(1)The bite-wing tab is a heavy paperboard tab or loop fitted around a periapical film or sensor and used to stabilize the receptor during exposure.(2)The periapical receptor is oriented in the bite loop so that the tab portion extends from the white side (tube side)of the film or sensor.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
سؤال
Which of the following exposure sequences is recommended for the patient who requires both periapical and bite-wing images?
1)Bite-wing exposures
2)Anterior periapical receptors
3)Posterior periapical receptors

A)1,2,3
B)2,1,3
C)2,3,1
D)3,1,2
سؤال
According to the text,the identification dot on the film in bite-wing placement

A)should be oriented "dot down."
B)should be oriented "dot distal."
C)should be oriented "dot up."
D)has no significance.
سؤال
Where should you position the mesial edge of the receptor when taking a premolar bite-wing image?

A)Midline of the maxillary canine
B)Midline of the mandibular canine
C)Mesial of the maxillary first premolar
D)Mesial of the mandibular first premolar
سؤال
Which size bite-wing receptor may be placed in a horizontal or vertical position?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
سؤال
The contacts on your dental image are closed.You will need to take a retake.What should you do in order to achieve open contacts on your retake dental image?

A)Direct the PID at a +10 degree vertical angulation.
B)Direct the PID at a -10 degree vertical angulation.
C)Direct the PID through the contacts of the teeth.
D)Stabilize the receptor when the patient bites.
سؤال
When determining vertical angulation,if the position-indicating device (PID)is positioned above the occlusal plane and the central ray is directed _______,the vertical angulation is termed _________.

A)upward;positive
B)downward;positive
C)upward;negative
D)downward;negative
سؤال
Where should you position the mesial edge of the receptor when taking a molar bite-wing image?

A)Distal of the maxillary first premolar
B)Distal of the mandibular first premolar
C)Midline of the maxillary second premolar
D)Midline of the mandibular second premolar
سؤال
You have a 4-year-old boy in your chair,which size receptor will you need to use to take bite-wing images on him?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/20
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 19: Bite-Wing Technique
1
When taking a molar bite-wing image,in order to follow rule number 5 of the bite-wing technique,receptor exposure,what must the mesial part of the PID cover?

A)Mesial of the mandibular first molar
B)Both first molars
C)Mesial of the mandibular second premolar
D)Both second premolars
Both second premolars
2
_______ sizes of bite-wing receptors are available.

A)Two
B)Three
C)Four
D)Six
Three
3
(1)Overlapped interproximal contacts are caused by improper vertical angulation.(2)To prevent overlap,the vertical angulation should be adjusted to +10 degrees.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
Both statements are false.
4
Vertical bite-wings are often used for patients with

A)mixed dentition.
B)extensive decay.
C)bone loss.
D)sealants.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
5
When taking a premolar bite-wing image,in order to follow rule number 5 of the bite-wing technique,receptor exposure,what must the mesial part of the PID cover?

A)Both premolars
B)Both canines
C)Mandibular canine
D)Mandibular premolar
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
6
In the adult patient,which size receptor is recommended for bite-wing exposures?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
7
The problem with a single bite-wing receptor per side for adult patients is increased

A)x-ray exposure.
B)possibility of inciting the gag reflex.
C)overlapped contacts.
D)useful diagnostic information.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
8
What vertical angulation should you use when adjusting the PID to take bite-wing images with bite-tabs?

A)-10 degrees
B)0 degrees
C)+5 degrees
D)+10 degrees
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
9
What modification in technique is recommended when the patient has an edentulous space causing a problem with bite-wing receptor placement?

A)Skip the bite-wing receptor.
B)Place a cotton roll in the area of the missing tooth or teeth.
C)Have the patient hold the receptor in position with a hemostat.
D)Take a periapical receptor with a bite-block instead.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
10
Your 35-year-old patient has clinical attachment loss in the posterior teeth.What type of bite-wing images should you take,and what size receptor should you use?

A)Horizontal;1
B)Horizontal;2
C)Vertical;1
D)Vertical;2
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
11
(1)Size 3 receptor can only be used for bite-wing images.(2)Size 3 receptor is the recommended size for adult bite-wing images.

A)Both statements are true
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
12
(1)The bite-wing tab is a heavy paperboard tab or loop fitted around a periapical film or sensor and used to stabilize the receptor during exposure.(2)The periapical receptor is oriented in the bite loop so that the tab portion extends from the white side (tube side)of the film or sensor.

A)Both statements are true.
B)Both statements are false.
C)The first statement is true;the second statement is false.
D)The first statement is false;the second statement is true.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
13
Which of the following exposure sequences is recommended for the patient who requires both periapical and bite-wing images?
1)Bite-wing exposures
2)Anterior periapical receptors
3)Posterior periapical receptors

A)1,2,3
B)2,1,3
C)2,3,1
D)3,1,2
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
14
According to the text,the identification dot on the film in bite-wing placement

A)should be oriented "dot down."
B)should be oriented "dot distal."
C)should be oriented "dot up."
D)has no significance.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
15
Where should you position the mesial edge of the receptor when taking a premolar bite-wing image?

A)Midline of the maxillary canine
B)Midline of the mandibular canine
C)Mesial of the maxillary first premolar
D)Mesial of the mandibular first premolar
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
16
Which size bite-wing receptor may be placed in a horizontal or vertical position?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
17
The contacts on your dental image are closed.You will need to take a retake.What should you do in order to achieve open contacts on your retake dental image?

A)Direct the PID at a +10 degree vertical angulation.
B)Direct the PID at a -10 degree vertical angulation.
C)Direct the PID through the contacts of the teeth.
D)Stabilize the receptor when the patient bites.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
18
When determining vertical angulation,if the position-indicating device (PID)is positioned above the occlusal plane and the central ray is directed _______,the vertical angulation is termed _________.

A)upward;positive
B)downward;positive
C)upward;negative
D)downward;negative
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
19
Where should you position the mesial edge of the receptor when taking a molar bite-wing image?

A)Distal of the maxillary first premolar
B)Distal of the mandibular first premolar
C)Midline of the maxillary second premolar
D)Midline of the mandibular second premolar
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
20
You have a 4-year-old boy in your chair,which size receptor will you need to use to take bite-wing images on him?

A)Size 0
B)Size 1
C)Size 2
D)Size 3
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 20 في هذه المجموعة.