Deck 16: Process Troubleshooting

ملء الشاشة (f)
exit full mode
سؤال
Primary operational problems are best described as:

A) Problems created or responded to during a process upset.
B) Catastrophic shutdown events.
C) A term used to describe the first problem that created a process upset.
D) Those conditions linked to hard wire interlocks.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
Identify the most important instrumentation used to troubleshoot process problems. Circle all that apply!

A) Control loops- pressure, temperature, level, flow, analytical
B) Analyzers and alarms
C) Video trends and chart recorders
D) Gauges & indicators
سؤال
Redundancy is a process that:

A) Shuts down the unit in an emergency.
B) Bypasses problem areas.
C) Stores spare parts in warehouse.
D) Uses backup systems for critical equipment.
سؤال
Check sheets are used to:

A) Qualification document for new technicians
B) Collect large quantities of data.
C) Approve purchase of equipment
D) Management document used in HR for OSHA employee checks.
سؤال
Process control instrumentation is used to:

A) Guide process production and quality.
B) Control each variable in the system.
C) Monitor each variable in the system.
D) B & C
سؤال
Troubleshooting the operation of process equipment requires: Circle all that apply!

A) Good understanding of basic equipment components
B) Good understanding of how the equipment operates
C) A technical degree
D) Five years experience with operating systems
سؤال
In the following graphic, what would happen if P-104 failed and could not be restarted?
In the following graphic, what would happen if P-104 failed and could not be restarted?   a. Steam flow will. . . - increase - decrease - stay the same b. Bottoms flow rate will. . . - increase - decrease - stay the same c. Bottoms temperature will. . . - increase - decrease - stay the same d. The bottoms level will. . . - increase - decrease - stay the same<div style=padding-top: 35px>
a. Steam flow will. . .
- increase
- decrease
- stay the same
b. Bottoms flow rate will. . .
- increase
- decrease
- stay the same
c. Bottoms temperature will. . .
- increase
- decrease
- stay the same
d. The bottoms level will. . .
- increase
- decrease
- stay the same
سؤال
In the following graphic, what would happen if the reflux control valve failed closed?
In the following graphic, what would happen if the reflux control valve failed closed?   a. Column pressure will. . . - increase - decrease - stay the same b. Reflux flow rate will. . . - increase - decrease - stay the same c. Column top temperature will. . . - increase - decrease - stay the same d. The level in D-100 will. . . - increase - decrease - stay the same<div style=padding-top: 35px>
a. Column pressure will. . .
- increase
- decrease
- stay the same
b. Reflux flow rate will. . .
- increase
- decrease
- stay the same
c. Column top temperature will. . .
- increase
- decrease
- stay the same
d. The level in D-100 will. . .
- increase
- decrease
- stay the same
سؤال
In the following graphic, what would happen if the hot oil system failed?
In the following graphic, what would happen if the hot oil system failed?   a. Reactor pressure will. . . - increase - decrease - stay the same b. Vapor production will. . . - increase - decrease - stay the same c. Agitation and catalyst flow will. . . - increase - decrease - stay the same d. The level in the reactor will. . . - increase - decrease - stay the same<div style=padding-top: 35px>
a. Reactor pressure will. . .
- increase
- decrease
- stay the same
b. Vapor production will. . .
- increase
- decrease
- stay the same
c. Agitation and catalyst flow will. . .
- increase
- decrease
- stay the same
d. The level in the reactor will. . .
- increase
- decrease
- stay the same
سؤال
In the following graphic, what would happen if the hot oil system in the reactor failed?
In the following graphic, what would happen if the hot oil system in the reactor failed?   a. Absorber column pressure will. . . - increase - decrease - stay the same b. Vapor recovery flow rate will. . . - increase - decrease - stay the same c. Vapor catalyst flow to separator will. - increase - decrease - stay the same d. The level in the columns will. . . - increase - decrease - stay the same<div style=padding-top: 35px>
a. Absorber column pressure will. . .
- increase
- decrease
- stay the same
b. Vapor recovery flow rate will. . .
- increase
- decrease
- stay the same
c. Vapor catalyst flow to separator will.
- increase
- decrease
- stay the same
d. The level in the columns will. . .
- increase
- decrease
- stay the same
سؤال
In this graphic, what would happen if CV-15 failed open?
In this graphic, what would happen if CV-15 failed open?   a. Tray 8 temperature will. . . - increase - decrease - stay the same b. Reflux flow rate will. . . - increase - decrease - stay the same c. P-104 flow rate will. . . - increase - decrease - stay the same d. P-103 flow rate will. . . - increase - decrease - stay the same<div style=padding-top: 35px>
a. Tray 8 temperature will. . .
- increase
- decrease
- stay the same
b. Reflux flow rate will. . .
- increase
- decrease
- stay the same
c. P-104 flow rate will. . .
- increase
- decrease
- stay the same
d. P-103 flow rate will. . .
- increase
- decrease
- stay the same
سؤال
List the four troubleshooting methods described in this chapter.
سؤال
List the five elements of a control loop.
سؤال
Draw a flow control loop.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/14
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 16: Process Troubleshooting
1
Primary operational problems are best described as:

A) Problems created or responded to during a process upset.
B) Catastrophic shutdown events.
C) A term used to describe the first problem that created a process upset.
D) Those conditions linked to hard wire interlocks.
A term used to describe the first problem that created a process upset.
2
Identify the most important instrumentation used to troubleshoot process problems. Circle all that apply!

A) Control loops- pressure, temperature, level, flow, analytical
B) Analyzers and alarms
C) Video trends and chart recorders
D) Gauges & indicators
Control loops- pressure, temperature, level, flow, analytical
Analyzers and alarms
Video trends and chart recorders
Gauges & indicators
3
Redundancy is a process that:

A) Shuts down the unit in an emergency.
B) Bypasses problem areas.
C) Stores spare parts in warehouse.
D) Uses backup systems for critical equipment.
Uses backup systems for critical equipment.
4
Check sheets are used to:

A) Qualification document for new technicians
B) Collect large quantities of data.
C) Approve purchase of equipment
D) Management document used in HR for OSHA employee checks.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
5
Process control instrumentation is used to:

A) Guide process production and quality.
B) Control each variable in the system.
C) Monitor each variable in the system.
D) B & C
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
6
Troubleshooting the operation of process equipment requires: Circle all that apply!

A) Good understanding of basic equipment components
B) Good understanding of how the equipment operates
C) A technical degree
D) Five years experience with operating systems
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
7
In the following graphic, what would happen if P-104 failed and could not be restarted?
In the following graphic, what would happen if P-104 failed and could not be restarted?   a. Steam flow will. . . - increase - decrease - stay the same b. Bottoms flow rate will. . . - increase - decrease - stay the same c. Bottoms temperature will. . . - increase - decrease - stay the same d. The bottoms level will. . . - increase - decrease - stay the same
a. Steam flow will. . .
- increase
- decrease
- stay the same
b. Bottoms flow rate will. . .
- increase
- decrease
- stay the same
c. Bottoms temperature will. . .
- increase
- decrease
- stay the same
d. The bottoms level will. . .
- increase
- decrease
- stay the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
8
In the following graphic, what would happen if the reflux control valve failed closed?
In the following graphic, what would happen if the reflux control valve failed closed?   a. Column pressure will. . . - increase - decrease - stay the same b. Reflux flow rate will. . . - increase - decrease - stay the same c. Column top temperature will. . . - increase - decrease - stay the same d. The level in D-100 will. . . - increase - decrease - stay the same
a. Column pressure will. . .
- increase
- decrease
- stay the same
b. Reflux flow rate will. . .
- increase
- decrease
- stay the same
c. Column top temperature will. . .
- increase
- decrease
- stay the same
d. The level in D-100 will. . .
- increase
- decrease
- stay the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
9
In the following graphic, what would happen if the hot oil system failed?
In the following graphic, what would happen if the hot oil system failed?   a. Reactor pressure will. . . - increase - decrease - stay the same b. Vapor production will. . . - increase - decrease - stay the same c. Agitation and catalyst flow will. . . - increase - decrease - stay the same d. The level in the reactor will. . . - increase - decrease - stay the same
a. Reactor pressure will. . .
- increase
- decrease
- stay the same
b. Vapor production will. . .
- increase
- decrease
- stay the same
c. Agitation and catalyst flow will. . .
- increase
- decrease
- stay the same
d. The level in the reactor will. . .
- increase
- decrease
- stay the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
10
In the following graphic, what would happen if the hot oil system in the reactor failed?
In the following graphic, what would happen if the hot oil system in the reactor failed?   a. Absorber column pressure will. . . - increase - decrease - stay the same b. Vapor recovery flow rate will. . . - increase - decrease - stay the same c. Vapor catalyst flow to separator will. - increase - decrease - stay the same d. The level in the columns will. . . - increase - decrease - stay the same
a. Absorber column pressure will. . .
- increase
- decrease
- stay the same
b. Vapor recovery flow rate will. . .
- increase
- decrease
- stay the same
c. Vapor catalyst flow to separator will.
- increase
- decrease
- stay the same
d. The level in the columns will. . .
- increase
- decrease
- stay the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
11
In this graphic, what would happen if CV-15 failed open?
In this graphic, what would happen if CV-15 failed open?   a. Tray 8 temperature will. . . - increase - decrease - stay the same b. Reflux flow rate will. . . - increase - decrease - stay the same c. P-104 flow rate will. . . - increase - decrease - stay the same d. P-103 flow rate will. . . - increase - decrease - stay the same
a. Tray 8 temperature will. . .
- increase
- decrease
- stay the same
b. Reflux flow rate will. . .
- increase
- decrease
- stay the same
c. P-104 flow rate will. . .
- increase
- decrease
- stay the same
d. P-103 flow rate will. . .
- increase
- decrease
- stay the same
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
12
List the four troubleshooting methods described in this chapter.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
13
List the five elements of a control loop.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
14
Draw a flow control loop.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 14 في هذه المجموعة.