Deck 20: Internal Walls and Partitions
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
سؤال
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
العب
ملء الشاشة (f)
Deck 20: Internal Walls and Partitions
1
A non-loadbearing partition 5.6m in length and 2.4m in height should have a minimum thickness of
A) 48mm
B) 60mm
C) 100mm
D) 112mm
E) 140mm
A) 48mm
B) 60mm
C) 100mm
D) 112mm
E) 140mm
B
2
Bricks used in the construction of partitions often have grooved surfaces to
A) Reduce their weight
B) Improve their sound absorption
C) Improve their strength
D) Improve their appearance
E) Provide a key for plaster
A) Reduce their weight
B) Improve their sound absorption
C) Improve their strength
D) Improve their appearance
E) Provide a key for plaster
E
3
Expanded metal fabric is used to
A) Strengthen the connection between block partitions at their junction
B) Strengthen the horizontal joints in brick partitions
C) Strengthen the vertical joints in block partitions
D) Resist thermal movement between adjoining solid partitions
E) Resist moisture movement between adjoining solid partitions
A) Strengthen the connection between block partitions at their junction
B) Strengthen the horizontal joints in brick partitions
C) Strengthen the vertical joints in block partitions
D) Resist thermal movement between adjoining solid partitions
E) Resist moisture movement between adjoining solid partitions
A
4
Solid partitions to upper floors can be supported by
A) Building them in stretcher bond
B) Building them over a rolled steel joist
C) Bonding them into the external walls
D) Locating them to coincide with ceiling joists
E) Building them parallel to the floor boards
A) Building them in stretcher bond
B) Building them over a rolled steel joist
C) Bonding them into the external walls
D) Locating them to coincide with ceiling joists
E) Building them parallel to the floor boards
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
A nogging is incorporated into a timber stud partition to
A) Connect the studs to the floor
B) Connect the studs to the ceiling
C) Connect the studs to the external wall
D) Stiffen the studs in their length
E) Provide the correct spacing between the studs
A) Connect the studs to the floor
B) Connect the studs to the ceiling
C) Connect the studs to the external wall
D) Stiffen the studs in their length
E) Provide the correct spacing between the studs
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
One advantage of metal stud partitions is
A) They have a low thermal transmittance coefficient
B) They have a high fire resistance
C) They have a low sound absorption coefficient
D) They have high tensile strength
E) They have a low density
A) They have a low thermal transmittance coefficient
B) They have a high fire resistance
C) They have a low sound absorption coefficient
D) They have high tensile strength
E) They have a low density
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
Solid separating walls need to be constructed of materials having
A) A maximum thermal conductance coefficient of 0.1 W/m2K
B) A maximum compressive strength of 1.0N/mm2
C) A minimum density of 600kg/m3
D) A maximum sound reduction of 30dB over the frequency range of 100-3150 Hz
E) A minimum moisture content of 15%
A) A maximum thermal conductance coefficient of 0.1 W/m2K
B) A maximum compressive strength of 1.0N/mm2
C) A minimum density of 600kg/m3
D) A maximum sound reduction of 30dB over the frequency range of 100-3150 Hz
E) A minimum moisture content of 15%
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
Loadbearing ground floor partitions usually transfer their load to the ground beneath by
A) Using a rolled steel joist spanning between the external walls
B) Using a prestressed concrete I beam spanning between the external walls
C) Using a timber wall plate bearing onto a sleeper wall
D) Thickening the ground floor slab
E) Constructing a raft slab foundation
A) Using a rolled steel joist spanning between the external walls
B) Using a prestressed concrete I beam spanning between the external walls
C) Using a timber wall plate bearing onto a sleeper wall
D) Thickening the ground floor slab
E) Constructing a raft slab foundation
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
For fire resistance purposes, a party wall should be built within
A) 25mm of the inside of the external wall
B) 15mm of the inside of the external wall
C) 25mm of the top of the roof truss
D) 15mm of the top of the roof truss
E) 10m of the building boundary
A) 25mm of the inside of the external wall
B) 15mm of the inside of the external wall
C) 25mm of the top of the roof truss
D) 15mm of the top of the roof truss
E) 10m of the building boundary
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
Hollow lightweight partitions often incorporate insulation to improve their
A) Thermal performance
B) Acoustic performance
C) Fire resistance
D) Impact resistance
E) Flexural resonance
A) Thermal performance
B) Acoustic performance
C) Fire resistance
D) Impact resistance
E) Flexural resonance
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck