Deck 11: Leak Testing

ملء الشاشة (f)
exit full mode
سؤال
The leak detection method that is widely accepted in the field for performing a leak-check on a newly installed, assembled or repaired system is the __________.

A) electronic leak detector test
B) halide leak detector test
C) vacuum test
D) standing pressure test
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
A relative humidity over __________ greatly increases the chances of allowing mold to grow in the occupied space.

A) 40%
B) 50%
C) 60%
D) 70%
سؤال
With the soap bubble method of leak detection,

A) larger leaks typically produce large bubbles
B) smaller leaks typically produce small bubbles
C) smaller leaks typically produce large bubbles
D) small leaks produce no bubble at all
سؤال
The desired relative humidity in an occupied space is in the __________% to __________% range, with ___________% being ideal.
سؤال
Via the use of a small internal pump, air is pushed out of the electronic leak detector and, if refrigerant is detected, the audible tone that the detector emits will change.
سؤال
The pressure that is used during the standing pressure test must not exceed the __________ factory test pressure.

A) average
B) highest
C) lowest
D) median
سؤال
The electronic leak detector has the ability to locate leaks as small as __________ ounce per year.

A) 0.125
B) 0.25
C) 0.5
D) 0.55
سؤال
To comply with laws set forth by the EPA, the technician should __________ pressurize a system for leak-checking purposes with 100 percent refrigerant.

A) always
B) never
C) occasionally
D) often
سؤال
Typically, the electronic leak detector emits a slow beeping sound that increases in __________ depending on the amount of refrigerant detected.

A) frequency
B) pitch
C) tone
D) volume
سؤال
Match between columns
relies on a dye that is added to the system
ultrasonic leak detector
relies on a dye that is added to the system
gauge manifold
relies on a dye that is added to the system
electronic leak detector
relies on a dye that is added to the system
halide leak detector
relies on a dye that is added to the system
soap bubbles
relies on a dye that is added to the system
ultraviolet leak detection
سؤال
Match between columns
is brushed onto the piping circuit, primarily at solder joints
ultrasonic leak detector
is brushed onto the piping circuit, primarily at solder joints
gauge manifold
is brushed onto the piping circuit, primarily at solder joints
electronic leak detector
is brushed onto the piping circuit, primarily at solder joints
halide leak detector
is brushed onto the piping circuit, primarily at solder joints
soap bubbles
is brushed onto the piping circuit, primarily at solder joints
ultraviolet leak detection
سؤال
Match between columns
uses an open flame to detect leaks of chlorinated refrigerants
ultrasonic leak detector
uses an open flame to detect leaks of chlorinated refrigerants
gauge manifold
uses an open flame to detect leaks of chlorinated refrigerants
electronic leak detector
uses an open flame to detect leaks of chlorinated refrigerants
halide leak detector
uses an open flame to detect leaks of chlorinated refrigerants
soap bubbles
uses an open flame to detect leaks of chlorinated refrigerants
ultraviolet leak detection
سؤال
The __________ method of leak detection is primarily used on systems that have already been put into service,

A) electronic leak detector
B) halide leak detector
C) ultrasonic leak detector
D) ultraviolet leak detector
سؤال
Air conditioning and refrigeration systems are intended to operate with the correct amount of refrigerant to help ensure efficient operation. List six problems that can result if a system operates from a deficiency of refrigerant.
سؤال
Systems should not be leak-tested by pulling the unit into a vacuum.
سؤال
Leak-checking a system prior to startup is an absolute must, especially when refrigerant lines are to be __________.

A) brazed
B) flared
C) sealed behind walls or ceilings
D) soldered
سؤال
Match between columns
is able to sense very small amounts of refrigerant in air samples
ultrasonic leak detector
is able to sense very small amounts of refrigerant in air samples
gauge manifold
is able to sense very small amounts of refrigerant in air samples
electronic leak detector
is able to sense very small amounts of refrigerant in air samples
halide leak detector
is able to sense very small amounts of refrigerant in air samples
soap bubbles
is able to sense very small amounts of refrigerant in air samples
ultraviolet leak detection
سؤال
Provide the formula by which The relative humidity is calculated.
سؤال
When a soap bubble solution is used to detect leaks in a system, the solution is __________ or __________ onto the piping circuit, primarily at __________. The formation of bubbles indicates that __________.
سؤال
After determining a safe pressure at which to perform the standard pressure test, the system can be pressurized. Nitrogen is a great choice for accomplishing this for what two reasons?
سؤال
List the steps for performing the standing pressure test, in the proper order.
سؤال
With the standing pressure test, the __________ the system stays under pressure, the more reliable the leak-check will be. On residential systems, __________ should be more than sufficient time for even the smallest leak to cause movement on the gauge. If at all possible, the system should be under pressure __________ to ensure that the system is leak-free prior to startup. If a _________ leak is present, the pressure in the system will begin to drop rapidly. __________ leaks may require much more time to show up on the gauge.
سؤال
Explain why leak testing a system is often one of the most difficult tasks a service technician can face.
سؤال
Match between columns
enables the technician to read both saturation temperatures and pressures within the system
ultrasonic leak detector
enables the technician to read both saturation temperatures and pressures within the system
gauge manifold
enables the technician to read both saturation temperatures and pressures within the system
electronic leak detector
enables the technician to read both saturation temperatures and pressures within the system
halide leak detector
enables the technician to read both saturation temperatures and pressures within the system
soap bubbles
enables the technician to read both saturation temperatures and pressures within the system
ultraviolet leak detection
سؤال
Match between columns
reacts to the sound of the escaping gas
ultrasonic leak detector
reacts to the sound of the escaping gas
gauge manifold
reacts to the sound of the escaping gas
electronic leak detector
reacts to the sound of the escaping gas
halide leak detector
reacts to the sound of the escaping gas
soap bubbles
reacts to the sound of the escaping gas
ultraviolet leak detection
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/25
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Leak Testing
1
The leak detection method that is widely accepted in the field for performing a leak-check on a newly installed, assembled or repaired system is the __________.

A) electronic leak detector test
B) halide leak detector test
C) vacuum test
D) standing pressure test
D
2
A relative humidity over __________ greatly increases the chances of allowing mold to grow in the occupied space.

A) 40%
B) 50%
C) 60%
D) 70%
C
3
With the soap bubble method of leak detection,

A) larger leaks typically produce large bubbles
B) smaller leaks typically produce small bubbles
C) smaller leaks typically produce large bubbles
D) small leaks produce no bubble at all
C
4
The desired relative humidity in an occupied space is in the __________% to __________% range, with ___________% being ideal.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
5
Via the use of a small internal pump, air is pushed out of the electronic leak detector and, if refrigerant is detected, the audible tone that the detector emits will change.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
6
The pressure that is used during the standing pressure test must not exceed the __________ factory test pressure.

A) average
B) highest
C) lowest
D) median
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
7
The electronic leak detector has the ability to locate leaks as small as __________ ounce per year.

A) 0.125
B) 0.25
C) 0.5
D) 0.55
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
8
To comply with laws set forth by the EPA, the technician should __________ pressurize a system for leak-checking purposes with 100 percent refrigerant.

A) always
B) never
C) occasionally
D) often
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
9
Typically, the electronic leak detector emits a slow beeping sound that increases in __________ depending on the amount of refrigerant detected.

A) frequency
B) pitch
C) tone
D) volume
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
10
Match between columns
relies on a dye that is added to the system
ultrasonic leak detector
relies on a dye that is added to the system
gauge manifold
relies on a dye that is added to the system
electronic leak detector
relies on a dye that is added to the system
halide leak detector
relies on a dye that is added to the system
soap bubbles
relies on a dye that is added to the system
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
11
Match between columns
is brushed onto the piping circuit, primarily at solder joints
ultrasonic leak detector
is brushed onto the piping circuit, primarily at solder joints
gauge manifold
is brushed onto the piping circuit, primarily at solder joints
electronic leak detector
is brushed onto the piping circuit, primarily at solder joints
halide leak detector
is brushed onto the piping circuit, primarily at solder joints
soap bubbles
is brushed onto the piping circuit, primarily at solder joints
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
12
Match between columns
uses an open flame to detect leaks of chlorinated refrigerants
ultrasonic leak detector
uses an open flame to detect leaks of chlorinated refrigerants
gauge manifold
uses an open flame to detect leaks of chlorinated refrigerants
electronic leak detector
uses an open flame to detect leaks of chlorinated refrigerants
halide leak detector
uses an open flame to detect leaks of chlorinated refrigerants
soap bubbles
uses an open flame to detect leaks of chlorinated refrigerants
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
13
The __________ method of leak detection is primarily used on systems that have already been put into service,

A) electronic leak detector
B) halide leak detector
C) ultrasonic leak detector
D) ultraviolet leak detector
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
14
Air conditioning and refrigeration systems are intended to operate with the correct amount of refrigerant to help ensure efficient operation. List six problems that can result if a system operates from a deficiency of refrigerant.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
15
Systems should not be leak-tested by pulling the unit into a vacuum.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
16
Leak-checking a system prior to startup is an absolute must, especially when refrigerant lines are to be __________.

A) brazed
B) flared
C) sealed behind walls or ceilings
D) soldered
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
17
Match between columns
is able to sense very small amounts of refrigerant in air samples
ultrasonic leak detector
is able to sense very small amounts of refrigerant in air samples
gauge manifold
is able to sense very small amounts of refrigerant in air samples
electronic leak detector
is able to sense very small amounts of refrigerant in air samples
halide leak detector
is able to sense very small amounts of refrigerant in air samples
soap bubbles
is able to sense very small amounts of refrigerant in air samples
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
18
Provide the formula by which The relative humidity is calculated.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
19
When a soap bubble solution is used to detect leaks in a system, the solution is __________ or __________ onto the piping circuit, primarily at __________. The formation of bubbles indicates that __________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
20
After determining a safe pressure at which to perform the standard pressure test, the system can be pressurized. Nitrogen is a great choice for accomplishing this for what two reasons?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
21
List the steps for performing the standing pressure test, in the proper order.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
22
With the standing pressure test, the __________ the system stays under pressure, the more reliable the leak-check will be. On residential systems, __________ should be more than sufficient time for even the smallest leak to cause movement on the gauge. If at all possible, the system should be under pressure __________ to ensure that the system is leak-free prior to startup. If a _________ leak is present, the pressure in the system will begin to drop rapidly. __________ leaks may require much more time to show up on the gauge.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
23
Explain why leak testing a system is often one of the most difficult tasks a service technician can face.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
24
Match between columns
enables the technician to read both saturation temperatures and pressures within the system
ultrasonic leak detector
enables the technician to read both saturation temperatures and pressures within the system
gauge manifold
enables the technician to read both saturation temperatures and pressures within the system
electronic leak detector
enables the technician to read both saturation temperatures and pressures within the system
halide leak detector
enables the technician to read both saturation temperatures and pressures within the system
soap bubbles
enables the technician to read both saturation temperatures and pressures within the system
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
25
Match between columns
reacts to the sound of the escaping gas
ultrasonic leak detector
reacts to the sound of the escaping gas
gauge manifold
reacts to the sound of the escaping gas
electronic leak detector
reacts to the sound of the escaping gas
halide leak detector
reacts to the sound of the escaping gas
soap bubbles
reacts to the sound of the escaping gas
ultraviolet leak detection
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 25 في هذه المجموعة.