Deck 2: Understanding the Inputoutput Io Section

ملء الشاشة (f)
exit full mode
سؤال
List at least two I/O modules that require shielded cable to reduce the effects of electrical noise.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
List three things to consider before installing a rack or chassis.
سؤال
The ____________________ type output module is used when dry reed relays are desirable.
سؤال
____________________ output modules are used for interfacing with discrete or integrated circuit (IC) TTL devices, LED displays, and various other 5 V DC devices.
سؤال
While it is important that the controller and programming unit be installed or mounted in a control center or other central location, the use of remote I/O racks allows the input and output modules to be installed close to the actual operating equipment.
سؤال
When an output module is connected positive and provides current to the outside world (output device), the module is referred to as ____________________.
سؤال
With solid-state control systems, proper ____________________ helps eliminate the effects of electromagnetic induction.
سؤال
PLCs with ____________________ I/O typically come in a complete unit that contains the processor, I/O section, and power supply.
سؤال
What is a Triac used for in an AC output module?
سؤال
Discrete I/O modules are types of modules that only accept digital or ON- and OFF-type signals.
سؤال
Describe electrical noise and how it is generated.
سؤال
Status lights are provided for each output point to indicate when that point has been turned OFF.
سؤال
The input/output section, or I/O section, is the major reason that PLCs are so versatile when used with process machines or driven equipment.
سؤال
The analog output module changes Binary or BCD values generated in the PLC logic into analog signals using an RTD.
سؤال
What is an I/O rack or chassis?
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 2: Understanding the Inputoutput Io Section
1
List at least two I/O modules that require shielded cable to reduce the effects of electrical noise.
Certain I/O modules such as TTL, analog, and thermocouples require shielded cable to reduce the effects of electrical noise.
2
List three things to consider before installing a rack or chassis.
Before installing a rack or chassis, consideration must be given to the following:
temperature
dust
vibration
humidity
field wiring distances
troubleshooting accessibility
3
The ____________________ type output module is used when dry reed relays are desirable.
reed relay
4
____________________ output modules are used for interfacing with discrete or integrated circuit (IC) TTL devices, LED displays, and various other 5 V DC devices.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
While it is important that the controller and programming unit be installed or mounted in a control center or other central location, the use of remote I/O racks allows the input and output modules to be installed close to the actual operating equipment.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
When an output module is connected positive and provides current to the outside world (output device), the module is referred to as ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
With solid-state control systems, proper ____________________ helps eliminate the effects of electromagnetic induction.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
PLCs with ____________________ I/O typically come in a complete unit that contains the processor, I/O section, and power supply.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
What is a Triac used for in an AC output module?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
Discrete I/O modules are types of modules that only accept digital or ON- and OFF-type signals.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
Describe electrical noise and how it is generated.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
Status lights are provided for each output point to indicate when that point has been turned OFF.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The input/output section, or I/O section, is the major reason that PLCs are so versatile when used with process machines or driven equipment.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
The analog output module changes Binary or BCD values generated in the PLC logic into analog signals using an RTD.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
What is an I/O rack or chassis?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.