Deck 42: Synchronous Automatic Motor Starter

ملء الشاشة (f)
exit full mode
سؤال
An automatic synchronous motor starter can be used with a synchronous motor to provide automatic control of the startup sequence.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The squirrel cage winding will overheat if a synchronous motor starts, accelerates, and reaches synchronous speed within a time interval determined to be normal for the motor.
سؤال
A synchronous motor is started by accelerating the motor to as high a speed as possible from the squirrel cage winding and then applying the DC field excitation.
سؤال
The coil of the field contactor is operated from the same direct-current source that provides excitation for the .

A)AC field winding
B)low inductive circuit
C)dynamic magnetic field
D)synchronous motor field
سؤال
In the brushless DC exciter, the commutator of a conventional direct-connected exciter is replaced with a three- phase, bridge-type, .

A)solid-state rectifier
B)controlled rectifier
C)direct transformer
D)small rectifier
سؤال
There are three basic methods of starting synchronous motors automatically.
سؤال
A solenoid-operated field contactor is similar in appearance to the standard contactor.

A)magnetic
B)AC
C)DC
D)polarized
سؤال
The development of the brushless DC exciter is an improvement in synchronous motor excitation.
سؤال
The field contactor opens to the source of excitation.

A)the top line
B)both lines
C)the second line
D)either of the two lines
سؤال
If the synchronous motor operates at subsynchronous speed, the squirrel cage winding may and be damaged.

A)subcool
B)restart
C)overheat
D)reset
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 42: Synchronous Automatic Motor Starter
1
An automatic synchronous motor starter can be used with a synchronous motor to provide automatic control of the startup sequence.
True
2
The squirrel cage winding will overheat if a synchronous motor starts, accelerates, and reaches synchronous speed within a time interval determined to be normal for the motor.
False
3
A synchronous motor is started by accelerating the motor to as high a speed as possible from the squirrel cage winding and then applying the DC field excitation.
True
4
The coil of the field contactor is operated from the same direct-current source that provides excitation for the .

A)AC field winding
B)low inductive circuit
C)dynamic magnetic field
D)synchronous motor field
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
In the brushless DC exciter, the commutator of a conventional direct-connected exciter is replaced with a three- phase, bridge-type, .

A)solid-state rectifier
B)controlled rectifier
C)direct transformer
D)small rectifier
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
There are three basic methods of starting synchronous motors automatically.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
A solenoid-operated field contactor is similar in appearance to the standard contactor.

A)magnetic
B)AC
C)DC
D)polarized
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
The development of the brushless DC exciter is an improvement in synchronous motor excitation.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
The field contactor opens to the source of excitation.

A)the top line
B)both lines
C)the second line
D)either of the two lines
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
If the synchronous motor operates at subsynchronous speed, the squirrel cage winding may and be damaged.

A)subcool
B)restart
C)overheat
D)reset
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.