Deck 40: Push-Button Synchronizing

ملء الشاشة (f)
exit full mode
سؤال
In the accompanying figure, the normally open contacts M in the F coil circuit prevent the DC field from being energized before the motor is started.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The discharge resistor the self-induced voltage from the collapsing DC magnetic field of the rotor windings.

A)dissipates
B)recovers
C)complements
D)increases
سؤال
The principal difference between synchronous motor control and induction motor control is in the control of the field.
سؤال
In the accompanying figure, the ammeter and rheostat control the excitation current.
سؤال
In the accompanying figure, the synchronous motor is started as an induction motor by the start button.

A)pulling
B)releasing
C)disconnecting
D)pressing
سؤال
In the accompanying figure, the overlapping normally closed contacts keep the loading resistor in the circuit.

A)F
B)L
C)M
D)T
سؤال
In the accompanying figure, the rotating magnetic field of the stator acts like a .

A)transformer primary
B)primary resistor starter
C)magnetic primary contactor
D)time-delay relay
سؤال
  In the accompanying figure, when the stator is energized, the rotor circuit must be open at all times.<div style=padding-top: 35px>
In the accompanying figure, when the stator is energized, the rotor circuit must be open at all times.
سؤال
There is one basic function of synchronous motor control in starting.
سؤال
<strong>  In the accompanying figure, the unity power factor of the motor can be found by adjusting the rheostat to obtain a minimum reading on the AC ammeter in the circuit.</strong> A)branch B)stator C)main D)rotor <div style=padding-top: 35px>
In the accompanying figure, the unity power factor of the motor can be found by adjusting the rheostat to obtain a minimum reading on the AC ammeter in the circuit.

A)branch
B)stator
C)main
D)rotor
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/10
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 40: Push-Button Synchronizing
1
In the accompanying figure, the normally open contacts M in the F coil circuit prevent the DC field from being energized before the motor is started.
True
2
The discharge resistor the self-induced voltage from the collapsing DC magnetic field of the rotor windings.

A)dissipates
B)recovers
C)complements
D)increases
A
3
The principal difference between synchronous motor control and induction motor control is in the control of the field.
True
4
In the accompanying figure, the ammeter and rheostat control the excitation current.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
5
In the accompanying figure, the synchronous motor is started as an induction motor by the start button.

A)pulling
B)releasing
C)disconnecting
D)pressing
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
6
In the accompanying figure, the overlapping normally closed contacts keep the loading resistor in the circuit.

A)F
B)L
C)M
D)T
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
7
In the accompanying figure, the rotating magnetic field of the stator acts like a .

A)transformer primary
B)primary resistor starter
C)magnetic primary contactor
D)time-delay relay
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
8
  In the accompanying figure, when the stator is energized, the rotor circuit must be open at all times.
In the accompanying figure, when the stator is energized, the rotor circuit must be open at all times.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
9
There is one basic function of synchronous motor control in starting.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
10
<strong>  In the accompanying figure, the unity power factor of the motor can be found by adjusting the rheostat to obtain a minimum reading on the AC ammeter in the circuit.</strong> A)branch B)stator C)main D)rotor
In the accompanying figure, the unity power factor of the motor can be found by adjusting the rheostat to obtain a minimum reading on the AC ammeter in the circuit.

A)branch
B)stator
C)main
D)rotor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 10 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon