Deck 9: Forward-Reverse Control

ملء الشاشة (f)
exit full mode
سؤال
What would happen if both contactors were energized at the same time?
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
____________________ forces one contactor to be de-energized before the other one can be energized.
سؤال
Electrical interlocking can be accomplished by connecting the normally closed ____________________ contacts on one contactor in series with the coil of the other contactor.
سؤال
Most reversing controllers only contain mechanical interlocks.
سؤال
Four methods of electrical interlocking are available.
سؤال
Figure 9-6
Figure 9-6   In the accompanying figure, the dashed lines drawn between the push buttons indicate that they are ____________________ connected.<div style=padding-top: 35px>
In the accompanying figure, the dashed lines drawn between the push buttons indicate that they are ____________________ connected.
سؤال
How are mechanical interlocks shown in a schematic diagram?
سؤال
Figure 9-12
Figure 9-12   The accompanying figure shows the components needed to construct a(n) ____________________ control circuit.<div style=padding-top: 35px>
The accompanying figure shows the components needed to construct a(n) ____________________ control circuit.
سؤال
How can the direction of rotation of any three phase motors be reversed?
سؤال
What does interlocking do?
سؤال
If R coil energizes, all R contacts change position.
سؤال
How is mechanical interlocking accomplished?
سؤال
The motor is connected to the power line regardless of which direction it operates.
سؤال
Magnetic reversing starters generally change T leads ____________________ and ____________________ to reverse the motor.
سؤال
One of the methods of electrical interlocking is accomplished with the use of double-acting push buttons.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/15
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 9: Forward-Reverse Control
1
What would happen if both contactors were energized at the same time?
Having both contactors energized would result in two of the three phase lines being shorted together.
2
____________________ forces one contactor to be de-energized before the other one can be energized.

Interlocking
3
Electrical interlocking can be accomplished by connecting the normally closed ____________________ contacts on one contactor in series with the coil of the other contactor.
auxiliary
4
Most reversing controllers only contain mechanical interlocks.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
5
Four methods of electrical interlocking are available.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
6
Figure 9-6
Figure 9-6   In the accompanying figure, the dashed lines drawn between the push buttons indicate that they are ____________________ connected.
In the accompanying figure, the dashed lines drawn between the push buttons indicate that they are ____________________ connected.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
7
How are mechanical interlocks shown in a schematic diagram?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
8
Figure 9-12
Figure 9-12   The accompanying figure shows the components needed to construct a(n) ____________________ control circuit.
The accompanying figure shows the components needed to construct a(n) ____________________ control circuit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
9
How can the direction of rotation of any three phase motors be reversed?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
10
What does interlocking do?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
11
If R coil energizes, all R contacts change position.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
12
How is mechanical interlocking accomplished?
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
13
The motor is connected to the power line regardless of which direction it operates.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
14
Magnetic reversing starters generally change T leads ____________________ and ____________________ to reverse the motor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
15
One of the methods of electrical interlocking is accomplished with the use of double-acting push buttons.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 15 في هذه المجموعة.