Deck 13: Switching Circuit Installation

ملء الشاشة (f)
exit full mode
سؤال
A permanent black marker can be used to reidentify a white insulated conductor as a "hot" ungrounded conductor in a cable.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
The brass-colored terminals on a three-way switch are called the __________ terminals.

A) common
B) traveler
C) ungrounded
D) grounded
سؤال
If the circuit-equipment grounding conductor is connected to the green grounding terminal on a switch, there is no need to ground the metal device box in which the switch is installed.
سؤال
Switches installed in metal boxes are considered grounded as long as metal screws are used to mount the switch's metal strap to a metal box that has an equipment-grounding wire connected to it.
سؤال
The black-colored common terminal on a three-way switch should always have a __________ insulated wire connected to it.

A) white
B) black
C) red
D) Any colored insulated wire is permitted
سؤال
Motor loads not exceeding 80% of the ampere rating of the switch at its rated voltage are permitted to be controlled by alternating current general-use snap switches.
سؤال
The most common switch used in residential wiring is the __________ switch.

A) double-pole switch
B) combination switch
C) three-way
D) single-pole
سؤال
The National Electrical Code requires that all switching be done in the __________ circuit conductor.

A) grounded
B) grounding
C) switch loop
D) ungrounded
سؤال
Switch loops are not permitted in three-way switch circuits.
سؤال
The white wire used in a traditional switch loop wired with a two-wire cable like Type NM must be reidentified.This is normally done with black electrical tape.
سؤال
When using three-wire Type NM cable the white insulated wire is sometimes used as a traveler conductor for three-way and four-way switching and is required to be reidentified as an ungrounded conductor.
سؤال
There is no need to connect a white insulated grounded conductor to any single-pole, double-pole, three-way, or four-way switch in a residential switching circuit.
سؤال
To control a lighting outlet from four locations, a circuit requires __________.

A) four single-pole switches
B) a four-way switch
C) two three-way switches and a four-way switch
D) two three-way switches and two four-way switches
سؤال
Dimmer switches are available in single-pole, three-way, and four-way models.
سؤال
A double-pole switch can be used to control two 120-volt circuits.
سؤال
Like single-pole toggle switches, single-pole dimmer switches always come from the factory with screw terminals.
سؤال
Like a four-way switch, a double-pole switch has four terminal screws and the toggle has "On" and "Off" written on it.
سؤال
When wiring a house using conduit, the NEC permits a white insulated conductor to be used as a "hot" conductor in a switch loop as long as it is reidentified as such.
سؤال
When reidentifying a white insulated conductor as a "hot" ungrounded conductor, the identifying mark must completely encircle the conductor.
سؤال
Four-way switches must be wired __________ in a switching circuit that has more than two switching locations.

A) before the three-way switches
B) in line with the three-way switches
C) after the three-way switches
D) between the three-way switches
سؤال
A switch type that raises or lowers the lamp brightness of a lighting fixture is a __________ switch.

A) two-way
B) dimmer
C) pilot light
D) combination
سؤال
A(n) ___________ is a device that detects when a person has entered a room and switches on the room lighting.

A) four-way switch
B) single-pole switch
C) dimmer switch
D) occupancy sensor
سؤال
____________________ switches are used to control one or more lighting loads from two or more locations.
سؤال
Explain where combination switches are usually installed in residential wiring systems.
سؤال
Which of the following switches tend to generate the most heat?

A) Double-pole switches
B) Dimmer switches
C) Three-way switches
D) Four-way switches
سؤال
The number of conductors required to be installed between three-way and four-way switches is ____________________.
سؤال
When wiring a house with a conduit wiring method, a __________ insulated wire cannot be used in a traditional switch loop as a "hot" ungrounded conductor.

A) red
B) white (re-identified)
C) blue
D) black
سؤال
Explain what must be done to a receptacle so that it may be split-wired with half of it "hot" and the other half switch-controlled.
سؤال
____________________ switch devices consist of two switches on one yoke or strap.
سؤال
Explain how to tell the difference between a four-way switch and a double-pole switch.
سؤال
A(n) ____________________ switch is used to control a 240-volt load, such as a water heater, in a residential wiring system.
سؤال
Explain how a traditional switch loop for a single-pole switch is wired using Type NM cable.
سؤال
When installing a ceiling-suspended paddle fan with a lighting kit, and you want to have separate control of the fan and light, a __________ must be run from the switching location to the paddle fan location.

A) two-wire cable
B) three-wire cable
C) four-wire cable
D) five-wire cable
سؤال
When wiring a house with a cable wiring method, a __________ insulated wire can be used in a switch loop switching arrangement.

A) red
B) white (reidentified)
C) black
D) All of the above
سؤال
A switching arrangement where the two-wire cable feed is brought to the lighting outlet first and a two-wire cable is installed from the lighting outlet to the switch is called a(n) _________________________.
سؤال
Three-way switches are always installed in __________.

A) pairs
B) threes
C) fours
D) None of the above
سؤال
Which of the following are the same as general-use snap switches?

A) Snap switches
B) Toggle switches
C) Switches
D) All of the above
سؤال
A ________ is a device that controls the flow of electricity on a circuit for a certain amount of time.

A) four-way switch
B) timer
C) motion sensor
D) single-pole switch
سؤال
Four-way switches are always wired between two __________ switches.

A) single-pole
B) double-pole
C) three-way
D) dimmer
سؤال
When installing a receptacle so that one half is controlled by a switch and the other half is "hot" all the time, the switch-controlled half should be located on the ____________________ of the receptacle.
سؤال
Explain why the top half of a split-wired receptacle is "hot" all the time and the switch-controlled half is on the bottom.
سؤال
Explain why one dimmer switch and one regular three-way switch are used in three-way circuits instead of two three-way dimmer switches.Assume the use of non-digital dimmers.
سؤال
Explain how a switch loop for a single-pole switch following the requirements of Section 404.2(C) is wired.Assume the use of Type NM cable.
سؤال
Describe benefits to using timers, motion sensors, and occupancy sensors in residential electrical systems.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/44
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 13: Switching Circuit Installation
1
A permanent black marker can be used to reidentify a white insulated conductor as a "hot" ungrounded conductor in a cable.
True
2
The brass-colored terminals on a three-way switch are called the __________ terminals.

A) common
B) traveler
C) ungrounded
D) grounded
B
3
If the circuit-equipment grounding conductor is connected to the green grounding terminal on a switch, there is no need to ground the metal device box in which the switch is installed.
False
The box must be grounded to maintain an adequate ground if the switch is removed from the device box.
4
Switches installed in metal boxes are considered grounded as long as metal screws are used to mount the switch's metal strap to a metal box that has an equipment-grounding wire connected to it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
5
The black-colored common terminal on a three-way switch should always have a __________ insulated wire connected to it.

A) white
B) black
C) red
D) Any colored insulated wire is permitted
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
6
Motor loads not exceeding 80% of the ampere rating of the switch at its rated voltage are permitted to be controlled by alternating current general-use snap switches.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
7
The most common switch used in residential wiring is the __________ switch.

A) double-pole switch
B) combination switch
C) three-way
D) single-pole
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
8
The National Electrical Code requires that all switching be done in the __________ circuit conductor.

A) grounded
B) grounding
C) switch loop
D) ungrounded
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
9
Switch loops are not permitted in three-way switch circuits.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
10
The white wire used in a traditional switch loop wired with a two-wire cable like Type NM must be reidentified.This is normally done with black electrical tape.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
11
When using three-wire Type NM cable the white insulated wire is sometimes used as a traveler conductor for three-way and four-way switching and is required to be reidentified as an ungrounded conductor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
12
There is no need to connect a white insulated grounded conductor to any single-pole, double-pole, three-way, or four-way switch in a residential switching circuit.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
13
To control a lighting outlet from four locations, a circuit requires __________.

A) four single-pole switches
B) a four-way switch
C) two three-way switches and a four-way switch
D) two three-way switches and two four-way switches
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
14
Dimmer switches are available in single-pole, three-way, and four-way models.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
15
A double-pole switch can be used to control two 120-volt circuits.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
16
Like single-pole toggle switches, single-pole dimmer switches always come from the factory with screw terminals.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
17
Like a four-way switch, a double-pole switch has four terminal screws and the toggle has "On" and "Off" written on it.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
18
When wiring a house using conduit, the NEC permits a white insulated conductor to be used as a "hot" conductor in a switch loop as long as it is reidentified as such.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
19
When reidentifying a white insulated conductor as a "hot" ungrounded conductor, the identifying mark must completely encircle the conductor.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
20
Four-way switches must be wired __________ in a switching circuit that has more than two switching locations.

A) before the three-way switches
B) in line with the three-way switches
C) after the three-way switches
D) between the three-way switches
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
21
A switch type that raises or lowers the lamp brightness of a lighting fixture is a __________ switch.

A) two-way
B) dimmer
C) pilot light
D) combination
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
22
A(n) ___________ is a device that detects when a person has entered a room and switches on the room lighting.

A) four-way switch
B) single-pole switch
C) dimmer switch
D) occupancy sensor
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
23
____________________ switches are used to control one or more lighting loads from two or more locations.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
24
Explain where combination switches are usually installed in residential wiring systems.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
25
Which of the following switches tend to generate the most heat?

A) Double-pole switches
B) Dimmer switches
C) Three-way switches
D) Four-way switches
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
26
The number of conductors required to be installed between three-way and four-way switches is ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
27
When wiring a house with a conduit wiring method, a __________ insulated wire cannot be used in a traditional switch loop as a "hot" ungrounded conductor.

A) red
B) white (re-identified)
C) blue
D) black
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
28
Explain what must be done to a receptacle so that it may be split-wired with half of it "hot" and the other half switch-controlled.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
29
____________________ switch devices consist of two switches on one yoke or strap.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
30
Explain how to tell the difference between a four-way switch and a double-pole switch.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
31
A(n) ____________________ switch is used to control a 240-volt load, such as a water heater, in a residential wiring system.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
32
Explain how a traditional switch loop for a single-pole switch is wired using Type NM cable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
33
When installing a ceiling-suspended paddle fan with a lighting kit, and you want to have separate control of the fan and light, a __________ must be run from the switching location to the paddle fan location.

A) two-wire cable
B) three-wire cable
C) four-wire cable
D) five-wire cable
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
34
When wiring a house with a cable wiring method, a __________ insulated wire can be used in a switch loop switching arrangement.

A) red
B) white (reidentified)
C) black
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
35
A switching arrangement where the two-wire cable feed is brought to the lighting outlet first and a two-wire cable is installed from the lighting outlet to the switch is called a(n) _________________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
36
Three-way switches are always installed in __________.

A) pairs
B) threes
C) fours
D) None of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
37
Which of the following are the same as general-use snap switches?

A) Snap switches
B) Toggle switches
C) Switches
D) All of the above
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
38
A ________ is a device that controls the flow of electricity on a circuit for a certain amount of time.

A) four-way switch
B) timer
C) motion sensor
D) single-pole switch
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
39
Four-way switches are always wired between two __________ switches.

A) single-pole
B) double-pole
C) three-way
D) dimmer
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
40
When installing a receptacle so that one half is controlled by a switch and the other half is "hot" all the time, the switch-controlled half should be located on the ____________________ of the receptacle.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
41
Explain why the top half of a split-wired receptacle is "hot" all the time and the switch-controlled half is on the bottom.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
42
Explain why one dimmer switch and one regular three-way switch are used in three-way circuits instead of two three-way dimmer switches.Assume the use of non-digital dimmers.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
43
Explain how a switch loop for a single-pole switch following the requirements of Section 404.2(C) is wired.Assume the use of Type NM cable.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
44
Describe benefits to using timers, motion sensors, and occupancy sensors in residential electrical systems.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 44 في هذه المجموعة.