Deck 13: Nondwelling Load Calculations

ملء الشاشة (f)
exit full mode
سؤال
To calculate multiple noncoincident loads used simultaneously, the ____ load(s) that will be used at one time is (are) used in calculating the total feeder/service load.

A) average
B) largest
C) medial
D) smallest
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
General-purpose receptacles are ____.

A) continuous loads
B) not allowed in commercial spaces
C) not included in the total load
D) not continuous loads
سؤال
Feeder conductors and overcurrent protection shall be sized at 100% of noncontinuous loads plus ____% of continuous loads.

A) 50
B) 75
C) 100
D) 125
سؤال
The feeder (or service) neutral load is the ____ of the load determined by Article 220.

A) maximum balance
B) minimum unbalance
C) maximum unbalance
D) minimum unbalance
سؤال
The demand factor for three pieces of equipment is 90%; for four pieces, ____%; for five pieces, 70%; and for more than five pieces, 65%.

A) 60
B) 70
C) 80
D) 90
سؤال
In calculating general lighting load, each floor's area shall be calculated using the building's (or area's) ____.

A) interior dimensions
B) outside dimensions
C) cross-sectional dimensions
D) cubic dimensions
سؤال
A load where the maximum current is expected to continue for ____ or more is a continuous load.

A) one hour
B) two hours
C) three hours
D) four hours
سؤال
In determining the load of the highest-rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous-duty motor full-load current multiplied by ____ shall be used in the summation.

A) 0.75
B) 1.25
C) 1.50
D) 1.75
سؤال
The load calculation form results (overcurrent protection and conductors) represent ____ requirement.

A) the complete
B) only a minimum
C) the first part of the
D) the written portion of the
سؤال
In office buildings, the receptacle load shall be calculated to be the larger of (1) the calculated load from 220.14(I), or (2) ____ volt-ampere(s) per square foot.

A) 1
B) 6
C) 8
D) 10
سؤال
Sign and outline lighting outlets in commercial buildings are computed at a minimum of ____ volt-amperes.

A) 600
B) 800
C) 1000
D) 1200
سؤال
Receptacle outlets are calculated at a minimum of ____ volt-amperes for each single (or multiple) receptacle on one yoke (or strap).

A) 180
B) 190
C) 195
D) 200
سؤال
Where the grounding electrode conductor or bonding jumper connects to a single or multiple rod, pipe, or plate electrode(s) or any combination thereof, or does not extend on to other types of electrodes that require a larger size conductor, the grounding electrode conductor shall not be required to be larger than ____.

A) 2 AWG copper wire or 4 AWG aluminum
B) 4 AWG copper wire or 6 AWG aluminum
C) 6 AWG copper wire or 4 AWG aluminum
D) 6 AWG copper wire or 8 AWG aluminum
سؤال
Fractions of an ampere 0.5 and higher are ____, while fractions less than 0.5 are dropped.

A) rounded up
B) applied exactly
C) rounded down
D) halved
سؤال
Conductors ____ AWG and larger can be connected in parallel (electrically joined at both ends to form a single conductor).

A) 1/0
B) 1/2
C) 1/3
D) 1/4
سؤال
The volt-ampere unit load for an office building is ____.

A) 1.3
B) 2.5
C) 3.0
D) 3.5
سؤال
Three-phase voltage is found by multiplying the voltage (single-phase) by ____.

A) 1.327
B) 1.732
C) 1.832
D) 1.914
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/17
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 13: Nondwelling Load Calculations
1
To calculate multiple noncoincident loads used simultaneously, the ____ load(s) that will be used at one time is (are) used in calculating the total feeder/service load.

A) average
B) largest
C) medial
D) smallest
B
2
General-purpose receptacles are ____.

A) continuous loads
B) not allowed in commercial spaces
C) not included in the total load
D) not continuous loads
D
3
Feeder conductors and overcurrent protection shall be sized at 100% of noncontinuous loads plus ____% of continuous loads.

A) 50
B) 75
C) 100
D) 125
D
4
The feeder (or service) neutral load is the ____ of the load determined by Article 220.

A) maximum balance
B) minimum unbalance
C) maximum unbalance
D) minimum unbalance
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
5
The demand factor for three pieces of equipment is 90%; for four pieces, ____%; for five pieces, 70%; and for more than five pieces, 65%.

A) 60
B) 70
C) 80
D) 90
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
6
In calculating general lighting load, each floor's area shall be calculated using the building's (or area's) ____.

A) interior dimensions
B) outside dimensions
C) cross-sectional dimensions
D) cubic dimensions
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
7
A load where the maximum current is expected to continue for ____ or more is a continuous load.

A) one hour
B) two hours
C) three hours
D) four hours
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
8
In determining the load of the highest-rated motor, the greater of either the ampere rating from 430.22(E) or the largest continuous-duty motor full-load current multiplied by ____ shall be used in the summation.

A) 0.75
B) 1.25
C) 1.50
D) 1.75
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
9
The load calculation form results (overcurrent protection and conductors) represent ____ requirement.

A) the complete
B) only a minimum
C) the first part of the
D) the written portion of the
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
10
In office buildings, the receptacle load shall be calculated to be the larger of (1) the calculated load from 220.14(I), or (2) ____ volt-ampere(s) per square foot.

A) 1
B) 6
C) 8
D) 10
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
11
Sign and outline lighting outlets in commercial buildings are computed at a minimum of ____ volt-amperes.

A) 600
B) 800
C) 1000
D) 1200
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
12
Receptacle outlets are calculated at a minimum of ____ volt-amperes for each single (or multiple) receptacle on one yoke (or strap).

A) 180
B) 190
C) 195
D) 200
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
13
Where the grounding electrode conductor or bonding jumper connects to a single or multiple rod, pipe, or plate electrode(s) or any combination thereof, or does not extend on to other types of electrodes that require a larger size conductor, the grounding electrode conductor shall not be required to be larger than ____.

A) 2 AWG copper wire or 4 AWG aluminum
B) 4 AWG copper wire or 6 AWG aluminum
C) 6 AWG copper wire or 4 AWG aluminum
D) 6 AWG copper wire or 8 AWG aluminum
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
14
Fractions of an ampere 0.5 and higher are ____, while fractions less than 0.5 are dropped.

A) rounded up
B) applied exactly
C) rounded down
D) halved
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
15
Conductors ____ AWG and larger can be connected in parallel (electrically joined at both ends to form a single conductor).

A) 1/0
B) 1/2
C) 1/3
D) 1/4
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
16
The volt-ampere unit load for an office building is ____.

A) 1.3
B) 2.5
C) 3.0
D) 3.5
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
17
Three-phase voltage is found by multiplying the voltage (single-phase) by ____.

A) 1.327
B) 1.732
C) 1.832
D) 1.914
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 17 في هذه المجموعة.