Deck 11: Count Control

ملء الشاشة (f)
exit full mode
سؤال
A typical electromechanical counter is generally available with digital set and readout dials.
استخدم زر المسافة أو
up arrow
down arrow
لقلب البطاقة.
سؤال
In some counters, the output contacts can be adjusted to perform in a specific manner.
سؤال
When the count motor has received the same number of count impulses as set on the dial, the contacts go the ____ condition.

A) counting
B) synchronous
C) counted-out
D) reset
سؤال
The electromechanical counter requires a minimum of approximately ____ seconds OFF time between input impulses to reset.

A) 0.5
B) 0.75
C) 2
D) 5
سؤال
The solid-state counter uses CMOS (complimentary metal-oxide semiconductor) integrated circuits for the ___ function.

A) energizing
B) deenergizing
C) counting
D) display
سؤال
When line voltage is applied to the count ____________________, incoming count pulses are not counted.
سؤال
In a typical solid-state counter, three counting modes can be programmed: count directional, ____________________, and quadrature.
سؤال
When the stepping motor is deenergized, the contacts return to the reset condition.
سؤال
The electromechanical control counter is similar to the electromechanical reset timer, except that the synchronous motor of the timer is replaced by a stepping motor. The stepping motor advances one step each time it is ____________________.
فتح الحزمة
قم بالتسجيل لفتح البطاقات في هذه المجموعة!
Unlock Deck
Unlock Deck
1/9
auto play flashcards
العب
simple tutorial
ملء الشاشة (f)
exit full mode
Deck 11: Count Control
1
A typical electromechanical counter is generally available with digital set and readout dials.
False
2
In some counters, the output contacts can be adjusted to perform in a specific manner.
True
3
When the count motor has received the same number of count impulses as set on the dial, the contacts go the ____ condition.

A) counting
B) synchronous
C) counted-out
D) reset
C
4
The electromechanical counter requires a minimum of approximately ____ seconds OFF time between input impulses to reset.

A) 0.5
B) 0.75
C) 2
D) 5
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
5
The solid-state counter uses CMOS (complimentary metal-oxide semiconductor) integrated circuits for the ___ function.

A) energizing
B) deenergizing
C) counting
D) display
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
6
When line voltage is applied to the count ____________________, incoming count pulses are not counted.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
7
In a typical solid-state counter, three counting modes can be programmed: count directional, ____________________, and quadrature.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
8
When the stepping motor is deenergized, the contacts return to the reset condition.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
9
The electromechanical control counter is similar to the electromechanical reset timer, except that the synchronous motor of the timer is replaced by a stepping motor. The stepping motor advances one step each time it is ____________________.
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.
فتح الحزمة
k this deck
locked card icon
فتح الحزمة
افتح القفل للوصول البطاقات البالغ عددها 9 في هذه المجموعة.